Contact specialized personnel for error codes
Code
Description
050
Shorted temperature probe
051
Open temperature probe.
Initial Fill Error. Initial fill
100
time was more than 4
minutes after power up.
Error on refill
101
Tank did not refill within 3
minutes.
102
Unwanted fill;
103
Liquid level probe fault
Heater open, high limit
201
thermostat, or Solid State
Relay (SSR) fault
INSERT
BREW
BASKET
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice

Error Codes

Possible Cause
Corrective Action
Probe failure.
Replace probe.
Bad probe
Check all connections.
connection, or
Replace probe if necessary.
probe failure.
Watch for short potting
Water supply flow
during brew cycle.
rate is too low.
Investigate cause of low flow
rate. (Clogged water filter...)
Watch for short potting
Water supply flow
during brew cycle.
rate is too low.
Investigate cause of low flow
rate. (Clogged water filter...)
Possible leak in
Check inside of machine for
tank, fitting, or
leaks.
valve.
Clean, check all
Probe fouled or
connections. Replace probe
shorts
if necessary.
SSR, High Limit,
Check and replace heating
or heating
elements if necessary.
element failure.
Brewbasket must
Insert brewbasket
be in place
16
How to Clear
Error Codes
TO CLEAR FAULT,
Make repairs as required
Below is the only way to
clear error codes
1) Enter
"PROGRAMMING"
2)Scroll left to "OTHER"
3)Scroll down to
"ERROR CODES"
4)Scroll down to "Display
Errors"
5)Scroll left to "Reset
Errors"
6)Scroll down to "Reset"
7)Follow directions
shown on screen.
Merely toggling ON/OFF
switch will not clear error
codes.
Error codes must be
cleared by entering
PROGRAMMING and
using the menus!