4.2.12 MSW12

●MSW 12-1: Bezel Function
Set the bezel function enabled/disabled.
[Outline]
ON (1) OPERATION:Bezel function is enabled and it works as per the setting of MSW12-2, MSW12-5 and
OFF (0) OPERATION: Bezel function is disabled.
●MSW12-2: LED Control
Set Bezel LED control enabled/disabled during stand-by, printing or ejecting.
[Outline]
ON (1) OPERATION:Bezel LED control is enabled.
OFF (0) OPERATION: Bezel LED control is disabled.
*Following initial settings can be changed by customize value command GS ( E.
*Regardless of MSW11-2 setting, bezel LED can be controlled by GS R 2 command.
●MSW12-5: Show Error by LED
Set error indication by bezel LED enabled/disabled.
[Outline]
ON (1) OPERATION:
OFF (0) OPERATION: Error indication by bezel LED is disabled.
Bezel Function
MSW12-6.
LED Control
Initial setting of bezel LED control
Initial setting of LED ON time at standby 0: LED ON continuously
Initial setting of LED blink ON/OFF time 5 seconds
When error occurs, bezel LED behaves same way as error LED synchronously.
Show Error by LED
Error indication by bezel LED is enabled.
OFF(0)
Invalid
OFF(0)
Invalid
Standby: LED OFF
Printing: LED ON
Ejecting: LED Blinking
OFF(0)
Invalid
- 433 -
ON(1)
Valid
ON(1)
Valid
ON(1)
Valid