fn=12: Function 12 Sending the Set Communication Conditions

GS ( E pL pH fn a
[Code]
<1D>H<28>H<45>H<pL><pH><fn><a>
[Range]
(pL+pH×256)=2 (pL=2, pH=0)
fn=12
1≤a≤4 (Does not send in other than specified range)
[Outline]
[The specification which is common to the model]
• Sends communication conditions of serial interface specified by "a".
Header
ID
Kind of communication conditions (a)
Separation number
Set value
NULL
• Set value
a=1: At specification of baud rate
◎---support by
CT-S280, CT-S281, CT-S2000, CT-S4000, CT-S801, CT-S851, CT-S601, CT-S651,
●---support by
CT-S280, CT-S2000, CT-S4000,
(
PMU2XXX
a=2: At specification of parity
a=3: At specification of flow control
a=4: At specification of data length
Baud Rate
d1
1200
49("1")
2400
50("2")
4800
52("4")
9600
57("9")
19200 (Default)
49("1")
38400
51("3")
●57600
53("5")
●115200
49("1")
PMU
does not support 57600bps.
d1
Parity Setting
48
49
50
d1
Flow Control
48
49
d1
Setting Data Length
48
49
Hex.
37H
33H
31H("1") to 34H("4")
1FH
30H to 39H
00H
d2
d3
50("2")
48("0")
52("4")
48("0")
56("8")
48("0")
54("6")
48("0")
57("9")
50("2")
56("8")
52("4")
55("7")
54("6")
49("1")
53("5")
series,
CT-P29x
series,
CT-S310II
does not support 115200bps)
CT-P29x series
No parity
Odd parity
Even parity
DTR/DSR
XON/XOFF
7-bit length
8-bit length
- 301 -
No. of Data
1
1
1
1
1 to 6
1
d4
D5
48("0")
-
48("0")
-
48("0")
-
48("0")
-
48("0")
48("0")
48("0")
48("0")
48("0")
48("0")
50("2")
48("0")
CT-S310II
d6
-
-
-
-
-
-
-
48("0")