XX REL POSITION
1-4
zz

*80 Menu Mode: Defining Output Functions

Use this mode to program output function definitions (up to 48 functions) that provide automated control of
any of the output devices, based on events occurring on individual zones or zones with certain zone types.
Each output definition is identified by an output function number, and includes the following components:
Output Definition Components
Component
Description
Output Function No.
A reference number that defines an output's characteristics.
Activated By
Determines whether the initiating event occurs on a zone, a zone list, or a zone type.
Event
Event that triggers the output action. Can be an event occurring on a specific zone number or
a zone list, or a specific zone type.
Partition
If the output is activated by zone type, this defines the partition in which the programmed
event is to cause the device action.
Output Action
Defines the action of the relay/X-10 device when the defined event occurs. Can close for 2
seconds, stay closed until reset, continuously pulse (1-second close-open-close-open, etc.),
toggle the device state, or activate for a defined duration (set in data field *177).
Output No.
Assigns this function to a specific output number (defined in *79 Menu Mode). This is the
output number that will perform this function upon the triggering event. Note that each
defined function is associated with only one output number. This means that if more than one
output device needs to perform this particular function, you need to define another output
function number with the same attributes, but assign the appropriate output number. (i.e.
output devices can be assigned more than one function number, but each function number can
only be assigned a single output number.
For example, if you want to pulse a strobe light upon fire alarms on zone 4 using a relay mapped to output
number 2 (as programmed in *79 Menu Mode), program the following in *80 Menu Mode:
Prompt
Output Funct. #
=
Activated By:
=
Enter Zn No.
=
Output Action
=
Output Number
=
Start Output Definition mode by pressing
∗ ∗ ∗ ∗ 80 Output Function Menu Mode
Output Funct. #
(00 = Quit)
01
01
A E P Trig
?00 0
0 – ZL=00
Relay Position
1-4 = relay position
[ ∗ ] to continue
This is the actual (or physical) relay number with respect to the Relay Module upon which
it is located. For 4204 modules, relay numbers are 1-4. For 4229 modules, relay numbers
are 1-2.
The system returns to the Output Number prompt for programming the next device.
NOTE: If using multi-mode, program the relays to trigger on those system events to be sent
to the user's email address. (4204 option = up to 4 events; 2-4204 option = up to 8 events)
See ∗29 Menu Mode section for enabling Multi-Mode.
Entry
01 (assuming this is the first output function)
3 (zone number)
04 (requires 2-digit zone numbers)
3 (continuous pulse)
02 (device mapped in *79 Menu Mode)
80 while in Data Programming mode.
Output Function No.
01-48 = output function number
[ ∗ ] to continue; 00 to quit
Enter the output function number to be defined (or 00 to exit).
Summary Screen
[ ∗ ] to continue
This screen displays a summary of the current output programming (for this example, Zone
List has been selected-this is the default screen).
A = Output Action; E = Triggering event; P = Partition; Trig = Trigger type
NOTE: A question mark in the summary screen indicates that the device number shown
has not been mapped. Use *79 Menu mode to map the device.
Menu Mode Programming
5-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista series vista-21ipsiaAdemco vista-21ipsiaAdemco vista-21ip

Table of Contents