TESTING THE SYSTEM
Using the Test mode allows each detection point to be checked for
proper operation. Testing should be conducted weekly to ensure
proper operation.
• The keypad sounds a single beep about every 30 seconds as a
reminder that the system is in the Test mode.
• Alarm messages are not sent to your Central Station while Test mode
is on.
If a problem is experienced with any detection point (no confirming
sounds, no display), call for service immediately.
1. Disarm the system and close all protected windows, doors, etc. The
READY indicator light should come on if all zones are intact
2. Enter your 4-digit Master code + 5 + 0 (walk)
3. Listen. The external sounder should sound for about 1 second then
turn off. If the sounder does not sound, CALL FOR SERVICE. The
"Test in Progress" display appears only on the keypad that started
the test.
4. Fault zones. Open each protected door and window in turn and
listen for three beeps from the keypad. Each faulted detection point
should appear on the display. The display clears when the door or
window is closed.
5. Walk in front of any interior motion detectors (if used) and listen for
three beeps. Each detector should appear on the display when it is
activated. The display clears when no motion is detected. Note that if
wireless motion detectors are used, there is a 3-minute delay between
activations to conserve battery life.
6. Test all smoke detectors, following the manufacturer's instructions.
7. When all detection points have been checked and are intact
(closed), there should be no zone numbers displayed.
8. Exit test mode: 4-digit code + 1
TROUBLE CONDITIONS
The word CHECK on the keypad's display, accompanied by a "beeping"
at the keypad, indicates a trouble condition in the system at the
displayed zone number sensor and requires your attention. Determine if
the zone(s) displayed are intact and make them so if they are not. If the
display persists, CALL FOR SERVICE.
To silence the beeping for these conditions, press any key.
Typical Trouble conditions include the following:
Trouble Message
Meaning
COMM. FAILURE
A failure has occurred in the telephone
(or FC)
communication portion of your system.
SYSTEM LO BAT
Low system battery condition exists.
(or BAT with no zone No.)
LO BAT+ zone descriptor
Low battery condition in the wireless transmitter.
(or BAT with zone No.)
Either replace the battery yourself, or CALL FOR
SERVICE.
Rcvr Jam (or CHECK 90)
RF interference in wireless system which may
impede reception from wireless sensors.
ALARM 1xx (or 91)
A communication problem between the control
FAULT 1xx
and a connected device (e.g., RF receiver, zone
CHECK 1xx
expander) where the "xx" indicates the device
address.
MODEM COMM (or CC)
Indicates that the control is on-line with the
Central Monitoring Station's remote computer.
BELL FAILURE (or CHECK 70)
Indicates that the wiring connection to the external
sounder is at fault.
AC LOSS (or NO AC)
The system is operating on battery power only due
to an AC power failure.
If only some lights are out on the premises, check
circuit breakers and fuses and reset or replace as
needed.
OPEN CIRCUIT
The keypad is not receiving signals from the
(or OC)
control.
Long Rng Trbl (or bF)
Communication device (if used) has failed.
TELCO FAULT (or CHECK 94)
The telephone line has a problem.
Busy-Standby
If this message remains displayed for more than 1
(or dI)
minute, system is disabled. CALL FOR SERVICE.
Ê800-22312aŠ
800-22312 7/16 Rev A
Part 1
SETTING THE DATE AND TIME
NOTE: All partitions must be disarmed before date/time can be set. You
can set the time and date by doing the following:
1.
+ [#] + [6] [3]
(Master Code)
2. Press [∗] when the time/date is displayed.
A cursor appears under the first digit of the hour.
To move cursor ahead, press [∗]. To go back, press [#].
• Enter the 2-digit hour setting.
• Enter the 2-digit minute setting.
• Press [1] for PM or [2] for AM.
• Enter the last two digits of the current year.
• Enter the 2-digit month setting.
• Enter the 2-digit day setting.
3. To exit, press [∗] when cursor is at the last digit, or wait 30 seconds.
NOTES
SERVICING INFORMATION
Your local Honeywell dealer is the person best qualified to service
your alarm system. Arranging some kind of regular service program
with him is advisable. Your local Honeywell dealer is:
Name:
Address:
Phone:
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2016 Honeywell International Inc.
www.honeywell.com/security
ADEMCO VISTA SERIES SECURITY SYSTEMS
VISTA-21iP / VISTA-21iPSIA
Quick Guide to User Functions
User Guide Available Online: This Quick Guide describes the most frequently used features and functions of your system. For full
details of all user functions, please see the system's User Guide located online at:
http://www.security.honeywell.com/hsc/products. The full version User Guide is also available from your installer upon request.
Congratulations on your ownership of a Honeywell Security System. This system provides:
• Three forms of detection: burglary, fire and emergency (see your installer for which forms of detection are installed)
• At least one keypad which provides control of system and displays system status
• Various sensors for perimeter and interior burglary detection
• Optional smoke or combustion detectors designed to provide early warning in case of fire.
Your system may also be programmed to automatically send alarm and status messages to a Central Monitoring Station.
SYSTEM BASICS
The following is a list of some of the most common features and
functions of your system:
• Several modes of burglary detection: Stay, Night-Stay, Away,
Instant, Maximum.
• Bypass feature lets you bypass selected zones while leaving the rest
of the system armed.
• Chime mode alerts you to the opening of protected doors and
windows while the system is disarmed.
• Fire and carbon monoxide detection are always active (if installed);
an alarm sounds if a fire or carbon monoxide condition is detected.
• Panic keys (if programmed) let you manually initiate fire and
personal alarms using the keypad.
• 4-digit security codes are used in conjunction with keypad
commands to perform system functions.
• Each user can be assigned a different security code, each with
different authority levels.
• The system sensors have been assigned to various "zones," which
are specific areas of detection (e.g., front door, kitchen window, etc.).
• Zone numbers (points of detection) are displayed at the keypad
when an alarm or trouble condition occurs.
• Partitions provide two independent areas of detection plus an
optional common area, with each partition containing a group of
zones that can be armed and disarmed without affecting other
zones or users.
• Function keys may have been programmed to perform various
functions. Ask your installer if these keys are active.
• A Scheduling feature can be programmed to automatically perform
certain functions (e.g., arm the system) at a predetermined time
each day. See the full User Guide for details.
ENTRY/EXIT DELAYS
• Entry Delays give you time to disarm the system when you enter
through the designated entrance door.
• You must disarm the system before the entry delay period ends, or
an alarm will occur (keypad beeps during the entry delay period,
reminding you to disarm the system).
• Exit delay gives you time after arming the system to leave through
the designated exit door(s) without setting off an alarm. If
programmed, a slow beeping will sound during the exit delay period
until the last 10 seconds, which then changes to fast beeping
(alerting you to the end of exit delay). If you cannot leave within this
delay time period, you should stop, disarm the system, and start
over to avoid a false alarm.
• See your installer for your delay times. See the full User Guide for
details on Exit Error alarms.
NOTES on BURGLARY DETECTION
• The system must be armed before the burglary detection can
sense intrusions.
• To arm your system, enter your security code followed by the
desired arming key.
• To disarm the system, enter your security code then press the
OFF key.
• When an alarm occurs, the keypad sounds and displays the
zone(s) causing the alarm. The external sounder may also sound.
• If your system is connected to a Central Monitoring Station, an
alarm message is also sent (delayed 30 seconds by default to
reduce false alarms).
• To stop the alarm sounding, simply disarm the system.
• Memory of Alarm: When an alarm condition occurs, the keypad
displays the number(s) of the zone(s) that caused the problem,
and displays the type of alarm. Clear the Memory of Alarm
display by entering another "off" sequence.
IMPORTANT: If you return to the premises and the
main burglary sounder is on, or the keypad beeps
rapidly upon entering the premises, it indicates that
an alarm has occurred during your absence and an
intruder may still be on the premises. LEAVE
IMMEDIATELY and CONTACT THE POLICE from a
nearby safe location.
NOTES on FIRE and CO DETECTION
• Your fire alarm system (if installed) is on 24 hours a day, for
continuous detection. In the event of an emergency, the smoke
and heat detectors sound their alarms, triggering a loud,
interrupted pulsed sound from the Keypad(s) and any external
sounders.
• You can silence the alarm at any time by pressing the OFF key
(the security code is not needed to silence fire alarms).
• Carbon monoxide (CO) detectors, if installed, provide continuous
detection. If a high level of carbon monoxide is detected, an
interrupted pulsed alarm sound occurs at the keypads and the
detector(s). Immediately move to a spot where fresh air is
available, preferably outdoors. From a safe area, call your security
service provider for further instructions. To silence the keypad
sounding, press the OFF key. To silence the detector, see its
instructions.

Advertisement

loading

Summary of Contents for Honeywell Vista-21ip

  • Page 1 User Guide located online at: READY indicator light should come on if all zones are intact http://www.security.honeywell.com/hsc/products. The full version User Guide is also available from your installer upon request. • Press [1] for PM or [2] for AM.
  • Page 2 CHECKING OPEN ZONES BYPASSING ZONES SECURITY CODES Checking Zones: Before arming your system, all protected doors, windows and other detection Your installer assigned a master code that is used to perform all system functions. Use the 6 BYPASS key when you want to arm your system with one or more zones intentionally zones must be closed or bypassed;...