2.3.4 Relay Strike Time

Factory setting for Relays 1 and 2 is 01 (1 Second).
System relays 1 and 2 are the two relays on the 1812 main circuit board. These steps will program relay 1 and relay 2 strike
times. Relay strike times can be programmed from 1/4 second - enter 0 0
step 3.
1. Press
2. Enter a relay number (1 or 2), then press
3. Enter the two-digit strike time (00-99), then press
4. Repeat steps 2 and 3 to set the other relay strike time if necessary.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.3.5 Tone Open Numbers

Factory setting is 9876 for Relay 1; 5432 for Relay 2.
These steps will program the tone open number(s) for each relay in the system (each relay is programmed independently).
You will need to enter a four-digit number (see chart below) to set each relay in step 3. If a function is not desired, enter #
in place of the digit. Use a different number for each of the four-digits in step 3 when multiple functions are desired.
Example 1: If you want the relay to have a "momentary activation" function only, and you want it to activate when the
number 9 is pressed, enter 9 # # #
Example 2: If you only want the relay to hold open when the number 8 is pressed and the relay deactivated when the
number 7 is pressed, enter # 8 7 #
1. Press
2. Enter a relay number (1 or 2), then press
3. Choose and enter a four-digit tone open number code (see chart below), then press
4. Repeat steps 2 and 3 to set the other relay tone open number(s) if desired.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
4 Digit Tone Open Number Code
1st Digit (Step 3)
2nd Digit (Step 3)
3rd Digit (Step 3)
4th Digit (Step 3)
Tone Open Number Factory Settings:
Relay 1
9
- Momentary Activation
8
- Hold Open
7
- Deactivate/Hang Up tone
6
- Hold Open 1 Hour
24
0 3 and enter the MASTER CODE. [
*
in step 3.
*
in step 3.
*
0 5 and enter the MASTER CODE. [
*
[ _ _ _ _
(beep)]
*
If a tone open function is not desired, enter # in place of a number.
Momentary activation. Relay will activate for its programmed relay strike time.
Hold open (latch). Relay will activate and remain activated until commanded to deactivate.
Deactivates an activated relay. Also hang up tone number to DENY ACCESS to guest.
Hold open 1 hour. Relay will activate for 1 hour and then deactivate itself.
5
- Momentary Activation
4
- Hold Open
3
- Deactivate/Hang Up tone
2
- Hold Open 1 Hour
*
0 3 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
*
. [ _ _
*
0 5 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
*
Function
Example for Relay 1 Factory Settings:
If you wish to GRANT ACCESS to a guest,
Relay 2
then dial "9" to open the gate.
If you wish to DENY ACCESS to a guest,
then dial "7" and Hang-Up.
in step 3, up to 99 seconds - enter 9 9
(beep)]
*
in
*
.
*
1812-065-V-12-14