BBQ GFS2616AD-1 Instruction Manual page 19

60k btu pro 4+1 burner grill
Table of Contents

Advertisement

Burner doesn't light using a
match
Sudden drop in gas flow or
reduced flame height
Irregular flame pattern, flame
does not run the full length of
burner
Flames turn yellow or orange
Flame blow out
Electrode cracked or broken -
sparks at crack
No gas flow
Coupling nut and regulator are
not fully connected
Blockage of gas flow
Disconnection of burner and
valve
Spider webs or insect nest in
venturi
Burner ports clogged or blocked
Out of gas
Burner ports are clogged or
blocked.
New burner may have residual
manufacturing oils
Spider webs or insect nest in
venturi
Food residue, grease or
seasoning salt on burner
Poor connection of valve to
burner venturi
High or gusting winds
- 19 -
Replace electrode
Check if propane tank is empty. If
not, refer to Excessive flow
safety valve reset procedure on
page
Turn off coupling nut about
one-half to three quarters
additional turn until solid stop.
Tighten by hand ONLY - DO
NOT use tools
Check burner tube and hose
Reconnect
Clean venturi
Clean burner ports
Replace cylinder
Clean burner ports
Burn your grill for 15 minutes with
the lid closed
Clean venturi
Clean burner
Assure burner venturi is properly
connected with valve
Turn front of grill to face wind or
increase flame height

Advertisement

Table of Contents
loading

Table of Contents