10. Install the FCM (fan control module) to the fl oor of the pedestal or bottom
heat shield with supplied magnets. Connect the FCM power cord to the
supplied extension cord and then run extension cord out the back of the
unit. See below.
Use strain relief grommet when running extension cord
Run the extension cord through the largest opening at
the back when using the Bottom Heat Shield with Legs
option–no strain relief grommet required.
919-512
12 |
Regency
CLASSIC C34-10 Direct Vent Freestanding Gas Stove
®
Diagram 8
through Pedestal
Diagram 9
11. Plug the fan into the FCM.
Caution: Ensure that the wires do not
touch any hot surfaces.
Note: The #8 ground lug is a dedicated ground for mobile home
use only.
IMPORTANT:
THESE FANS COLLECT A LOT OF
DUST FROM WITHIN YOUR HOME.
ENSURE YOU MAINTAIN THESE FAN
MOTORS ON A REGULAR BASIS BY
VACUUMING THE FAN BLADES AND
THE HOUSING WITH A SOFT BRUSH
NOZZLE.
FAN REMOVAL
1. Disconnect the power to the fan.
2. Allow the stove to cool to room temperature.
3. Open the pedestal door and remove the screws on the door cover plate.
(Leg units: remove the bottom access panel.)
4. Unplug the fan from the FCM.
5. Loosen the screws of the nutserts.
6. Remove the fan assembly from the key slots at the fan base and pull fan
out through the rectangular opening. (Diagram 5).
7. Turn fan 90 degrees. (Diagram 5). (Pedestal units only).
8. Disconnect the green ground wires to the grounding lug.
9
Remove fan from stove. (Diagram 3)
Diagram 10