CAUTION - The brewer must be disconnected from the power source until specifi ed in Initial Set-Up.
WHITE
WHITE
NEUTRAL
NEUTRAL
L1 BLACK
L1 BLACK
GREEN
GREEN
The brewer requires either 2-wire, grounded service rated 120 volts ac, or 3-wire, grounded service rated
120/208 or 120/240 volts ac, 20 amp, single phase, 60 Hz. Refer to the product's dataplate above the dilution
nozzle for actual voltage of your particular brewer model.
Electrical Hook-Up
CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specifi ed.
2. Remove top lid and rotate the control thermostat knob fully counterclockwise to the "OFF" position and replace
top lid.
3. Remove the lower rear panel, feed the cord through the strain relief at the rear of the brewer and connect it
to the terminal block.
4. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
5. Connect the brewer to the power source and verify voltage at the terminal block.
6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing
has been hooked up, the brewer is ready for Initial Set-Up.
WARNING - The brewer must be electrically grounded using the green screw near the terminal block. Do not
assume a plumbing line will provide an adequate ground.
The brewer must be connected to a cold water system with operating pressure between 30 and 90 psi(207
and 621 kPa) from a
1
" or larger supply line. A shut-off valve should be installed in the line before the brewer.
2
Install a regulator in the line when pressure is greater than 90 psi(621 kPa) to reduce it to 50 psi(345 kPa). The
water inlet fi tting is
1
" fl are.
4
NOTE - Bunn-O-Matic recommends
feet from the
1
" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer
2
to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The
size and shape of the hole made in the supply line by this type of device may restrict water fl ow.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual
of the Food and Drug Administration (FDA), this equipment must be installed with adequate backfl ow pre-
vention to comply with federal, state and local codes. For models installed outside the U.S.A., you must
comply with the applicable Plumbing /Sanitation Code for your area.
1. Attach the female fi tting from the short piece of tubing on the strainer/fl ow control (supplied) to the water
inlet fi tting at the rear of the brewer.
2. Flush the water line and securely attach it to the fl are fi tting on the strainer/fl ow control.
3. Turn on the water supply.

ELECTRICAL REQUIREMENTS

N
120V. A.C.
L1
G
120V AC
Single phase models

PLUMBING REQUIREMENTS

1
" copper tubing for installations of less than 25 feet and
4
L2 RED
WHITE
NEUTRAL
L1 BLACK
GREEN
Page 5
L2 RED
L2
120V. A.C.
WHITE
N
208 or 240V. A.C.
NEUTRAL
120V. A.C.
L1 BLACK
L1
GREEN
G
120/208 & 120/240V AC
Single phase models
3
" for more than 25
8
10777 051012

Advertisement

Table of Contents