Setting The Temperature

To change the heat temperature setting, push the
temperature setting. The floor and air heating can be shut off by holding the
until Set Room is Off. To resume heating when the Mode is Off, press the
to navigate to the Mode setting, then press the
thermostat will resume heating at the last previously set temperature.
The thermostat can operate on a programmable schedule. To change the temperatures
for the other time periods, enter the Settings menu by pressing both the
buttons together.
The thermostat can operate the heating system based on either an air or floor
sensor or a combination of both the air and floor temperature sensors together.
Air Temperature Only - ---- - - - - - - - - - - - - - - - - - - - - - - - - -- - -- - - -- - - - --- - --
If there is only an air temperature sensor (no floor sensor), the thermostat operates
to control your desired air temperature.
Floor Temperature Only - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- -- - - - -- - -
If the air sensor has been disabled, the thermostat will only maintain floor temperature
and ignore air temperature. This operation is recommended for areas such as
bathrooms to ensure that tile floors are warm to the touch.
Floor and Air Temperature - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - -- --
If the air sensor is turned on and a floor sensor is connected, the thermostat will
maintain the desired air temperature as well as a minimum floor temperature.
This operation is recommended for areas with large windows that allow the sun to
shine into a room and keep it warm without the need for heating. This can allow
the floors to cool off during the afternoon. When the sun goes down, it can take
a long time for the floors to get warm again. This may cause the room to cool off
too much in the early evening. A floor minimum setting can help with this condition
by maintaining a floor minimum temperature. Keep in mind the floor minimum
temperature will override the air temperature, and if set too high, may overheat
the room.
This operation is also recommended for rooms with hardwood floors. Setting floor
minimum and maximum temperatures is a way of enhancing the comfort of the
living space while protecting floor coverings.
90°F (32°C)
Feels hot to the touch
80 to 85°F (26 to 30°C)
Feels warm to the touch
70°F (21°C)
Feels cool to the touch
40 to 45°F (5 to 7°C)
Feels cold to the touch
A Watts Water Technologies Company
- ---- - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - ---- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Suggested maximum for all floor
types other than wood.
Bathrooms and kitchens. Suggested
maximum for wood floors.
Rooms with large windows preventing
under heating in the evening.
Freeze protection for garages.
3 of 4
or
button to select a preferred
button to select Mode Heat. The
© 2015
button
button
and
532_U - 02/15

Advertisement

loading