Boiler Model; Max. Boiler Temperature; Max. Allow. Operating Pressure; Heating Surface Area - Viessmann VITOROND 200 VD2A-125 Installation Instructions Manual

Vd2a series oil-/gas-fired boiler
Hide thumbs Also See for VITOROND 200 VD2A-125:
Table of Contents

Advertisement

Vitorond 200, VD2A Series Installation
Technical Data
(continued)

Boiler Model

Max. boiler temperature

(=fixed high limit)

Max. allow. operating pressure

Boiler connections
*6
Boiler supply and return
Drain valve - sediment faucet

Heating surface area

Flue gas side
Water side

Flue gas

*5
– Temperature (gross)
*7
– Flue gas mass flow rate
With minimum heating input and a 2-stage burner (operation of stage 1)
– Temperature
– Flue gas mass flow rate
at minimum input rate
Boiler standby loss based on max.
heating input and hot water supply
and return temperatures
of 167 / 140°F (75 / 60°C)

Vent pipe collar outer 7

Flue gas resistance

Flue gas volume

of combustion chamber and flue
gas passageways

Required flue draft

Category I

Positive pressure

Category III
*4
The maximum supply operating temperature (= max. adjustable high limit) lies approx. 27°F (15°C) below the
fixed high limit setting.
*5
May be less in some Canadian provinces.
*6
Connections for boiler connection kit (standard equipment).
*7
Combustion results are based on 13.0% CO
supply temperature of 167°F (75°C), and a system return temperature of 140°F (60°C). Measured flue gas
temperature with a combustion air temperature of 68°F (20°C) and a boiler water temperature of 176°F (80°C).
*8
Vent pipe collar diameter does not automatically indicate vent/chimney size. See page 30 for different venting
options (categories).
The combustion burner head material must be suitable for temperatures of at least 932°F (500°C).
For information regarding other Viessmann System Technology componentry, please reference documentation of
respective product.
VD2A-
*4
°F (°C)
*5
psig
in.
in.
ft.
(m
)
2
2
ft.
(m
)
2
2
°F (°C)
lbs/h (kg/h)
°F (°C)
lbs/h (kg/h)
%
in. (mm)
*8
"w.c.
ft.
3
(m
3
)
Pa ("w.c.)
Pa ("w.c.)
with fuel oil #2 and 10% CO
2
125
160
250 (121)
250 (121)
85
85
¾
¾
53 (4.9)
70 (6.5)
43 (4.0)
57 (5.3)
365 (185)
365 (185)
470 (213)
602 (273)
257 (125)
257 (125)
282 (128)
362 (164)
0.40
0.38
8 (200)
8 (200)
0.26
0.38
4.909
6.039
(0.139)
(0.171)
0 (0)
0 (0)
20 (0.08)
20 (0.08)
Additional Information
195
230
250 (121)
250 (121)
85
85
¾
¾
85 (7.9)
102 (9.5)
71 (6.6)
85 (7.9)
365 (185)
365 (185)
732 (332)
864 (390)
257 (125)
257 (125)
439 (199)
516 (234)
0.28
0.25
8 (200)
8 (200)
0.40
0.48
7.169
8.299
(0.203)
(0.235)
0 (0)
0 (0)
20 (0.08)
20 (0.08)
with natural gas, as well as a system
2
270
250 (121)
85
¾
117 (10.9)
99 (9.2)
365 (185)
1014 (457)
257 (125)
604 (274)
0.25
8 (200)
0.64
9.429
(0.267)
0 (0)
20 (0.08)
39