Gree GWHD14NK3BO Service Manual page 29

Hide thumbs Also See for GWHD14NK3BO:
Table of Contents

Advertisement

(2)GWHD(24)NK3EO:
1 Remove the valve cover at the right side plate of the
outdoor unit (one screw).
Remove the cable clamp, connect the power connection
2
cable with the terminal at the row of connection and fix
the connection. The fitting line distributing must be
consistent with the indoor unit. terminal of line bank.
Wiring should meet that of indoor unit.
3.
Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
Install the valve cover.
5.
To the power supply
Front Panel
To unit A
L
Power
connection
cord
cable
L
Indoor unit
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connectiong wirings of
the unit A ,unit B and unit C must be corresponding to
each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Do not install the outdoor unit where it is exposed
to the sunlight.
Note: the above figures are only intended to be a simple
diagram of the appliance and may not correspond to
the appearance of the units that have been purchased.
valve cover
To unit B
To unit C
connection
connection
cable
cable
Installation Manual
Outdoor unit
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents