Change for Life Service Manual Models: GWHD(14)NK3DO GWHD(18)NK3KO GWHD(21)NK3KO GWHD(24)NK3MO GWHD(28)NK3KO (Refrigerant R410A) GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI...
Service Manual Part Ⅰ : Technical Information 1. Summary Outdoor Unit GWHD(14)NK3DO GWHD(18)NK3KO GWHD(21)NK3KO GWHD(24)NK3MO GWHD(28)NK3KO Technical Information...
Service Manual 2. Specifications Model GWHD(14)NK3DO(LCLH) GWHD(14)NK3DO Product Code CB228W06500 CB228W06501 Rated Voltage 220-240 220-240 Power Rated Frequency supply Phases Cooling capacity(max~min) 4100(2052~4396) 4100(2052~4396) Heating capacity(max~min) 4400(2491~5422) 4400(2491~5422) Cooling Power Input(max~min) 1200 1200 Heating Power Input(max~min) 1180 1180 Cooling Current Input 5.32...
Page 5
Cross-sectional Area of Power Cable Conductor Recommended Power Cable(Core) Connection Pipe Connection Method Flare Connection Flare Connection Not Additional Gas Connection Pipe Length Connection Pipe Gas Additional Charge Outer Diameter of Liquid Pipe(GREE Allocation) Φ6 Φ6 (Metric) Outer Diameter of Gas Pipe(GREE Allocation) Φ9.52 Φ9.52...
Page 6
Service Manual Model GWHD(18)NK3KO(LCLH) GWHD(18)NK3KO Product Code CB228W06300 CB228W06301 Rated Voltage 220-240 220-240 Power Rated Frequency supply Phases Cooling capacity(max~min) 5200(2140~5800) 5200(2140~5800) Heating capacity(max~min) 5400(2579~5920) 5400(2579~5920) Cooling Power Input(max~min) 1450 1450 Heating Power Input(max~min) 1450 1450 Cooling Current Input 6.88 6.88 Heating Current Input 6.43...
Cross-sectional Area of Power Cable Conductor Recommended Power Cable(Core) Connection Pipe Connection Method Flare Connection Flare Connection Not Additional Gas Connection Pipe Length Connection Pipe Gas Additional Charge Outer Diameter of Liquid Pipe(GREE Allocation) Φ6 Φ6 (Metric) Outer Diameter of Gas Pipe(GREE Allocation) Φ9.52 Φ9.52...
Page 8
Service Manual Model GWHD(21)NK3KO(LCLH) GWHD(21)NK3KO Product Code CB228W06400 CB228W06401 Rated Voltage 220-240 220-240 Power Rated Frequency supply Phases Cooling capacity(max~min) 6100(2198~7327) 6100(2198~7327) Heating capacity(max~min) 6500(3605~8499) 6500(3605~8499) Cooling Power Input(max~min) 1910 1910 Heating Power Input(max~min) 1730 1730 Cooling Current Input 8.47 8.47 Heating Current Input 7.68...
Cross-sectional Area of Power Cable Conductor Recommended Power Cable(Core) Connection Pipe Connection Method Flare Connection Flare Connection Not Additional Gas Connection Pipe Length Connection Pipe Gas Additional Charge Outer Diameter of Liquid Pipe(GREE Allocation) Φ6 Φ6 (Metric) Outer Diameter of Gas Pipe(GREE Allocation) Φ9.52 Φ9.52...
Page 10
Service Manual Model GWHD(24)NK3MO(LCLH) GWHD(24)NK3MO Product Code CB228W06600 CB228W06601 Rated Voltage 220-240 220-240 Power Rated Frequency supply Phases Cooling capacity(max~min) 7100(2286~8499) 7100(2286~8499) Heating capacity(max~min) 8500(3664~8792) 8500(3664~8792) Cooling Power Input(max~min) 2180 2180 Heating Power Input(max~min) 2280 2280 Cooling Current Input 9.67 9.67 Heating Current Input 10.12...
Cross-sectional Area of Power Cable Conductor Recommended Power Cable(Core) Connection Pipe Connection Method Flare Connection Flare Connection Not Additional Gas Connection Pipe Length Connection Pipe Gas Additional Charge Outer Diameter of Liquid Pipe(GREE Allocation) Φ6 Φ6 (Metric) Outer Diameter of Gas Pipe(GREE Allocation) Φ9.52 Φ9.52...
Page 12
Service Manual Model GWHD(28)NK3KO(LCLH) GWHD(28)NK3KO Product Code CB228W06200 CB228W06201 Rated Voltage 220-240 220-240 Power Rated Frequency supply Phases Cooling capacity(max~min) 8000(2286~10258) 8000(2286~10258) Heating capacity(max~min) 9300(3664~10258) 9300(3664~10258) Cooling Power Input(max~min) 2540 2540 Heating Power Input(max~min) 2490 2490 Cooling Current Input 15.71 15.71 Heating Current Input 11.05...
Page 13
Cross-sectional Area of Power Cable Conductor Recommended Power Cable(Core) Connection Pipe Connection Method Flare Connection Flare Connection Not Additional Gas Connection Pipe Length Connection Pipe Gas Additional Charge Outer Diameter of Liquid Pipe(GREE Allocation) Φ6 Φ6 (Metric) Outer Diameter of Gas Pipe(GREE Allocation) Φ9.52 Φ9.52...
Service Manual 5. Electrical Part 5.1 Wiring Diagram ●Instruction Symbol Symbol Color Symbol Symbol Color Symbol Name White GREEN COMP Compressor Yellow Brown Grouding wire Blue YEGN Yellow/Green Black Violet Orange Outdoor Unit ● (1)Models:GWHD(14)NK3DO(CB228W06500) GWHD(18)NK3KO(CB228W06300) Technical Information...
Page 18
Service Manual (2)Model:GWHD(14)NK3DO(CB228W06501) GWHD(18)NK3KO(CB228W06301) (3)Model:GWHD(21)NK3KO(CB228W06400) Technical Information...
Page 19
Service Manual (4)Model:GWHD(21)NK3KO(CB228W06401) (5)Model:GWHD(24)NK3MO(CB228W06600) Technical Information...
Page 20
Service Manual (6)Model:GWHD(24)NK3MO(CB228W06601) (5)Model:GWHD(28)NK3KO(CB228W06200) Technical Information...
Page 21
Service Manual (6)Model:GWHD(28)NK3KO(CB228W06201) These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit. Technical Information...
Service Manual 5.2 PCB Printed Diagram 14/18K ● Top view Overload protection terminal of compressor Terminal of temperature sensor High-pressure protection terminal Low-pressure protection terminal Terminal of outdoor fan Electric heating terminal of chassis 4-way valve terminal Electric heating terminal of compressor Terminal of electronic expansion valve A...
Page 23
Service Manual 21/24/28K ● Top view Terminal of compressor Low-pressure protection terminal High-pressure protection terminal Overload protection terminal of compressor Terminal of temperature sensor Electric heating terminal of chassis Electric heating terminal of compressor Terminal of outdoor fan 4-way valve terminal 2-way valve termina 气阀、液阀接口电路...
Service Manual 6. Function and Control 1 Basic functions of the system 1.1 Cooling Mode 1.1.1 Cooling conditions and process: If the compressor is in stop status and start the unit for cooling operation, when one of the indoor units reaches the cooling operation condition, the unit start cooling operation;...
Service Manual 1.3.3 Outdoor fan control in heating mode The outdoor fan starts before 5s of the starting of compressor and then it will run in high speed for 40s; The fan shall run at every speed for at least 80s; When the compressor stops, the outdoor fan stops after 1min.
Service Manual 2.4 Communication malfunction Detection of the quantity of installed indoor units: After 3min of energizing, if the outdoor unit does not receive the communication data of certain indoor unit, the outdoor unit will judge that indoor unit is not installed and will treat it as it is not installed. If the outdoor unit receives the communication data of that indoor unit later, the outdoor unit will treat that unit as it is installed.
Service Manual Part Ⅱ : Installation and Maintenance 7. Notes for Installation and Maintenance Safety Precautions: 10. If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire Important! from the manufacture or distributor. Prohibit prolong the wire by yourself.
Page 28
Service Manual Main Tools for Installation and Maintenance 1. Level meter, measuring tape 2. Screw driver 3. Impact drill, drill head, electric drill 4. Electroprobe 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 7. Electronic leakage detector 8.
Service Manual 8. Installation Manual Installation procedures Start installation Preparation before installation Read the requirements select installation Prepare tools for electric connection location Select indoor unit Select outdoor unit installation location installation location Install wall-mounting Install the support of outdoor unit (select it according to the actual situation) frame, drill wall holes Connect pipes of indoor...
Service Manual 8.1 Electrical Connections GWHD(14)NK3DO GWHD(14)NK3DO GWHD(18)NK3KO 1. Remove the handle at the right side plate of the outdoor Handle unit (one screw). 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection.
Page 31
Service Manual GWHD(21)NK3KO GWHD(24)NK3MO GWHD(21)NK3KO 1. Remove the handle at the right side plate of the outdoor unit Handle (one screw). 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection.
Page 32
Service Manual GWHD(28)NK3KO 1. Remove the handle at the right side plate of the outdoor unit An all-pole disconnection switch having a contact (one screw). separation of at least 3mm in all pole should be connected 2. Remove the cable clamp, connect the power connection in fixed wiring.
Service Manual 8.2 Installing the Outdoor Unit Install the drain fitting and the drain hose(for model with Use bolts to secure the unit to a flat, solid floor. Install the drain fitting and the drain hose(for heat pump only) When mounting the unit on a wall or the roof, make Do not install the outdoor unit in pits or air vents model with heat pump only) sure the support is firmly secured so that it cannot...
Service Manual 8.3 Installation Dimension Diagram Use suitable instruments for the refrigerant R410A. ● Do not use any other refrigerant than R410A. Do not use mineral oils to clean the unit. The installation must be done by trained and qualified service personnel with reliability according to this manual. Contact service center before installation to avoid the malfunction due to unprofessional installation.
Service Manual 8.4 Check after Installation Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises May cause unsatisfactory cooling (heating) Has the gas leakage been checked? effect Is the thermal insulation of the unit May cause condensation and water dropping sufficient? May cause condensation and water dropping...
Service Manual 9. Maintenance 9.1 Precautions before Performing Inspection or Repair There are high-capacity electrolytic capacitors on the outdoor mainboard. Thus, even the power is cut off, there is high voltage inside the capacitors and it needs more than 20min to reduce the voltage to safety value. Touching the electrolytic capacitor within 20min after cutting the power will cause electric shock.
Service Manual 9.2 Flashing LED of Indoor/Outdoor Unit and Primary Judgement 1. Requirement of malfunction display When several malfunctions happen at the same time, malfunction codes will be displayed circularly. 2. Malfunction display method (1) Hardware malfunction: it will be displayed immediately, please refer to “Malfunction status sheet”; (2) Operation status: it will be displayed immediately, please refer to “Malfunction status sheet”;...
Communication failure with Unit A Communication failure with Unit A Communication failure with Unit B Communication failure with Unit B Service Manual Communication failure with Unit C Communication failure with Unit C Communication failure with Unit D Communication failure with Unit D Unit A freeze protection Unit A freeze protection Viewing malfunction code...
Page 39
Service Manual Energize the unit Please check: 1. if the indoor and outdoor heat exchanges are dirty, if there is obstacle to affect the radiation; 2. if the indoor and outdoor fans are running normally; If the above cases are existed? 3.
Page 40
Service Manual 2. PFC protection malfunction, capacity charging malfunction Main checking points: If the wiring of the induction is connected well and if the induction is broken; If the mainboard is broken; Flow chart: For 14/18K Start Check if power supply is normal Turn on the unit after power supply Power supply is abnormal?
Page 41
Service Manual For 21/24/28K Start Check If the power supply is normal Turn on the unit after the power supply resumes to Power supply is abnormal normal situation Check if the outdoor induction is broken Malfunction is eliminated Replace the outdoor mainboard Installation and Maintenance...
Page 42
Service Manual 3. Compressor desynchronizing malfunction Main checking points: If the pressure of the system is too high; If the eletric expansion valve is working normally or it is broken; If the radiation of the unit is good; Flow chart: The unit appears desynchronizing as soon as energizing and starting The stop duration of the compressor is longer...
Page 43
Service Manual Desynchronizing happens during operation Check if fan Replace the fan capacitor Outdoor unit is working? terminal is connected well Improve radiation situation of the unit Unit radiation is good? (such as cleaning Replace the outdoor unit the heat exchanger, improve ventilation Turn on the unit after the power...
Page 44
Service Manual 4. Compressor overload, diacharge protectionmalfunction Main checking points: If the eletric expansion valve is connected well or it is broken; If there is refrigerant leakage; If the overload protector is broken; Flow chart: Start If the overload protector is connected well? Check the resistance between the two ends of the overload protector in ambient temperature, if the resistance is below 1k...
Page 45
Service Manual 5. Start failuremalfunction Main checking points: If the connection wire of the compressor is connected properly; If the stop duration of the compressor is sufficient; If the compressor is broken; If the refrigerant charging amount is too much; Flow chart: Energize and start the unit...
Page 46
Service Manual 6. Temperature sensor malfunction Main checking points: If the temperature sensor is damaged or broken If the terminal of the temperature sensor is loosended or not connected; If the mainboard is broken; Flow chart: Start Check whether the wiring terminal between temperature sensor and controller is loosened or poorly contacted? Insert the temperature...
Page 47
Service Manual 7. DC fan malfunction Main checking points: If the outdoor fan is blocked by foreign objects; The connection wire of DC fan is connected reliably? If it is loose? Flow chart: Start Turn on the unit Check if the after removing the outdoor fan is blocked by foreign objects...
Page 48
Service Manual 8. Communication malfunction Main checking points: If the connection wire between the indoor unit and outdoor unit is connected well, if the wires inside the unit is connected well; If the indoor mainboard or outdoor main board is broken; Flow chart: Communication malfunction of some indoor units...
Page 49
Service Manual All the indoor units appear communication malfunction De-energize,check if the connection wire of indoor and outdoor unit and the wire of the eletric box is connected correctly Reconnect according to Eliminate the malfunction Connected correctly? the wiring diagram De-energize, check if the connection wire between the outdoor mainboard and the filter board according to the wiring diagram...
Page 50
Service Manual 9. Anti-high temperatureand overload malfunction Main checking points: If the outdoor ambient temperature is within the normal range; If the indoor fan and outdoor fan are running normally; If the indoor and outdoor radiation environment is good; Flow chart: Start It is a normal protection, please If the outdoor ambient temperature...
Service Manual 9.4 Maintenance Method for Normal Malfunction 1. Air Conditioner Can't be Started Up Possible Causes Discriminating Method (Air conditioner Status) Troubleshooting Confirm whether it's due to power failure. If yes, No power supply, or poor After energization, operation indicator isn’t bright wait for power recovery.
Page 52
Service Manual 4. ODU Fan Motor Can't Operate Possible causes Discriminating method (air conditioner status) Troubleshooting Connect wires according to wiring diagram to Wrong wire connection, or poor Check the wiring status according to circuit make sure all wiring terminals are connected connection diagram firmly...
Service Manual 10. Exploded View and Parts List Model:GWHD(14)NK3DO(CB228W06501) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 54
Service Manual Part Code Description GWHD(14)NK3DO Product Code CB228W06501 Front Grill 22413046 Cabinet 01433034P Chassis Sub-assy 01700000013P Gas-liquid Separator 07223048 Drainage Joint 26113009 Compressor Gasket 76710247 Compressor and fittings 00105249G Magnet Coil 4300040045 4-way Valve Assy 03015200041 Temperature Sensor 39000073...
Page 55
Service Manual Model:GWHD(14)NK3DO(CB228W06500) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 56
Service Manual Part Code Description GWHD(14)NK3DO Product Code CB228W06500 Front Grill 22413046 Cabinet 01433034P Chassis Sub-assy 01700000013P Gas-liquid Separator 07223048 Drainage Joint 26113009 Compressor Gasket 76710247 Compressor and fittings 00105249G Magnet Coil 4300040045 4-way Valve Assy 03015200041 Temperature Sensor 39000073...
Page 57
Service Manual Model:GWHD(18)NK3KO(CB228W06301) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 58
Service Manual Part Code Description GWHD(18)NK3KO Product Code CB228W06301 Front Grill 22413045 Front Panel 01535013P Chassis Sub-assy 0280326301P Drainage Connecter 06123401 Drainage hole Cap 06813401 Gas-liquid Separator Assy 07225017 Compressor and fittings 00105249G Magnet Coil 4300040045 4-Way Valve Assy 03073156 Right Side Plate 01303268P Valve Support Assy...
Page 59
Service Manual Model:GWHD(18)NK3KO(CB228W06300) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 60
Service Manual Part Code Description GWHD(18)NK3KO Product Code CB228W06300 Front Grill 22413045 Front Panel 01535013P Chassis Sub-assy 02803263P Drainage Connecter 06123401 Drainage hole Cap 06813401 Gas-liquid Separator Assy 07225017 Compressor and fittings 00105249G Electrical Heater 7651300403 Magnet Coil 4300040045 4-Way Valve Assy 03073156 Right Side Plate 01303268P...
Page 61
Service Manual Model:GWHD(21)NK3KO(CB228W06401) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 62
Service Manual Part Code Description GWHD(21)NK3KO Product Code CB228W06401 Front grill 22413045 Front Panel 01535013P Chassis Sub-assy 01700000120P Drainage Connecter 06123401 Compressor and fittings 0010524501 Compressor Gasket 76713066 Gas-liquid Separator Assy 07225017 Inhalation Tube 03500600586 Right Side Plate 01303268P Valve support assy 0713395501 Cut off Valve 07130239...
Page 63
Service Manual Model:GWHD(21)NK3KO(CB228W06400) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 64
Service Manual Part Code Description GWHD(21)NK3KO Product Code CB228W06400 Front grill 22413045 Front Panel 01535013P Chassis Sub-assy 01700000120P Drainage Connecter 06123401 Compressor and fittings 0010524501 Compressor Gasket 76713066 Gas-liquid Separator Assy 07225017 Inhalation Tube 03500600586 Right Side Plate 01303268P Valve support assy 0713395501 Cut off Valve 07130239...
Page 65
Service Manual Model:GWHD(24)NK3MO(CB228W06601) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 66
Service Manual Part Code Description GWHD(24)NK3MO Product Code CB228W06601 Front Grill 22413026 Cabinet 01435004P Left Handle 26235401 Front Side Plate 01305086P Drainage Connecter 06123401 Chassis Sub-assy 0280328001P Gas-liquid Separator Assy 07225017 Compressor and Fittings 0010524501 Tube Connector Sub-assy 06643008 4-Way Valve Assy 03073181 Connection Pipe 05113723...
Page 67
Service Manual Model:GWHD(24)NK3MO(CB228W06600) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 68
Service Manual Part Code Description GWHD(24)NK3MO Product Code CB228W06600 Front Grill 22413026 Cabinet 01435004P Left Handle 26235401 Front Side Plate 01305086P Electrical Heater (Chassis) 7651000411 Drainage Connecter 06123401 Chassis Sub-assy 02803280P Gas-liquid Separator Assy 07225017 Compressor and Fittings 0010524501 Electric Heater(Compressor) 7651873215 Tube Connector Sub-assy 06643008...
Page 69
Service Manual Model:GWHD(28)NK3KO(CB228W06201) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 70
Service Manual Part Code Description GWHD(28)NK3KO Product Code CB228W06201 Front Grill 22413048 Cabinet 01435004P Left Handle 26235401 Front Side Plate 01305086P Drainage Connecter 06123401 Chassis Sub-assy 0280328001P Gas-liquid Separator Assy 07225017 Compressor and Fittings 0010524501 Tube Connector Sub-assy 06643008 4-Way Valve Assy 03073181 Connection Pipe 05113723...
Page 71
Service Manual Model:GWHD(28)NK3KO(CB228W06200) The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
Page 72
Service Manual Part Code Description GWHD(28)NK3KO Product Code CB228W06200 Front Grill 22413048 Cabinet 01435004P Left Handle 26235401 Front Side Plate 01305086P Electrical Heater (Chassis) 7651000411 Drainage Connecter 06123401 Chassis Sub-assy 02803280P Gas-liquid Separator Assy 07225017 Compressor and Fittings 0010524501 Electric Heater(Compressor) 7651873215 Tube Connector Sub-assy 06643008...
Service Manual 11. Removal Procedure Warning: Be sure to wait for a minimum of 20 minutes after turning off all power supplies and discharge the refrigerant completely before removal. NOTE:only grille has some differences Step rocedure 1. Before disassembly Complete axonometric drawing. 2.
Page 74
Service Manual Step rocedure 4. Remove top panel top panel Remove the connection screws connecting the top panel and the front panel, and then remove the top panel. 5. Remove front grille Remove the connection screws connecting the front grille and the front panel, and then loosen the clasp to remove the front grille.
Page 75
Service Manual Step rocedure 7. Remove right side plate right side plate Remove the screws connecting the right side plate with the chassis and the valve support. Then remove the right side plate. 8. Remove rear grill Remove the screws connecting the rear grill and left side plate, and then remove the rear grill.
Page 76
Service Manual Step rocedure 10. Remove axial flow blade Remove the nut on the blade and then remove the axial flow blade. axial flow blade 11. Remove motor and motor support Remove the 4 tapping screws fixing the motor and disconnect the leading wire insert of the motor.
Page 77
Service Manual Step rocedure 13. Remove 4-way valve assy Unsolder the welding joint connecting the 4-way valve assy with compressor suction and discharge port, the valve with the outlet pipe of condenser. Then lift the 4-way valve 4-way valve assy to remove it. assy (NOTE: Discharge the refrigerant completely before unsoldering.)
Page 78
Service Manual Step rocedure 16. Remove compressor compressor Remove the 3 foot nuts fixing the compressor and then remove the compressor. 17. Remove condenser assy Remove the screws fixing the condenser support and then remove the condenser support. condenser assy Remove the screws connecting the condenser support and the chassis assy, and then remove the condenser assy.
Page 79
Service Manual 18/21K NOTE:Only cut-off valve of valve support, electronic expansion valve and coil have some differences Steps Procedure 1. Before disassembly Complete axonometric drawing. 2. Remove valve cover valve cover Remove the connection screw fixing the valve cover and then remove the valve cover. 3.
Page 80
Service Manual Step rocedure 4. Remove front grille Remove the connection screws connecting the front grille and the front panel, and then loosen the clasp to remove the front grille. grille 5. Remove front panel Remove the screws connecting the front panel and then remove the front panel.
Page 81
Service Manual Step rocedure 7. Remove rear grill rear grill Remove the screws connecting the rear grill and the left side plate, and then remove the rear grill. 8. Remove left side plate Remove the screws fixing the left side plate with the chassis and the condenser support, and then remove the left side plate.
Page 82
Service Manual Step rocedure 10. Remove axial flow blade Remove the nut on the blade and then remove the axial flow blade. axial flow blade 11. Remove motor and motor support Remove the 4 tapping screws fixing the motor and disconnect the leading wire insert of the motor.
Page 83
Service Manual Step rocedure 13. Remove PFC induction Remove the screw connecting the PFC induction and middle isolation sheet, and then remove the PFC induction PFC induction 14. Remove 4-way valve assy and suction pipe sub-assy 4-way valve assy Unsolder the welding joint connecting the 4-way valve assy with compressor suction and discharge port, the valve with the outlet pipe of condenser.
Page 84
Service Manual Step rocedure 16. Remove middle isolation sheet Remove the screws connecting the middle isolation sheet with the chassis assy and the condenser assy, and then remove the middle isolation sheet. middle isolation sheet 17. Remove compressor compressor Remove the 3 foot nuts fixing the compressor and then remove the compressor.
Page 85
Service Manual Step rocedure 19. Remove electronic expansion valve assy Unsolder the welding joint connecting the electronic expansion valve sub-assy with the gas collection pipe, and then remove the electronic expansion valve assy. (Note: when unsoldering, wrap the gas valve with a wet cloth completely to avoid damage to the valve caused by high temperature).
Page 86
Service Manual 24/28K NOTE:Only cut-off valve of valve support, electronic expansion valve and coil have some differences Steps Procedure 1. Remove valve cover and top panel valve cover Twist off the screws used for fixing and valve cover , pull v alve cover up ward to remove it. Remove the 3 screws connecting the top top panel panel with the front panel and the right side...
Page 87
Service Manual Remove the 5 screws connecting the panel with the chassis and the motor support, and then remove the panel. panel 3. Remove right side plate and left side plate right side plate Remove the scre ws connecting the right side plate with the chassis, the valve support and the electric box, and then remove the right side plate assy .
Page 88
Service Manual 4. Remove fan motor and axial flow blade axial flow blade Remove the nuts fixing the blade and then remove the axial flow blade. fan motor fixing frame Remove the 4 tapping screws fixing the motor; disconnect the leading wire insert of the motor and then remove the motor.
Page 89
Service Manual 6.Remove soundproof sponge and 4-way valv e assy soundproof sponge Since the piping ports on the soundproof sponge are torn easily, remove the soundproof sponge carefully 4-way valv e assy Discharge the refrigerant completely;unsolder the pipelines connecting the compressor and the condenser assy,and then remove the 4-way valve assy.
Page 90
Service Manual 8. Remov e Cut off Valve and Valve Support Remove the 2 bolts fixing the valve subassemblies. Unsolder the welding joint connecting the gas valve and the return air pipe. Remove the gas valve. (Note: When unsoldering the soldering joint, wrap the gas valve with wet cloth completely to avoid damage valve support to the valve caused by high temperature.)
Page 91
Service Manual condenser sub-assy 11.Remove condenser sub-assy Remove the chassis sub-assy and condenser sub-assy. chassis sub-assy Installation and Maintenance...
Service Manual Appendix: Appendix 1: Reference Sheet of Celsius and Fahrenheit Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32 Set temperature Fahrenheit Fahrenheit Fahrenheit display Fahrenheit display Fahrenheit display Fahrenheit Celsius (℃) Celsius (℃) Celsius (℃) temperature temperature temperature (℉)...
Service Manual Appendix 3: Pipe Expanding Method Pipe Note: Pipe cutter Improper pipe expanding is the main cause of refrigerant leakage.Please expand the pipe according to the following steps: Leaning Uneven Burr A:Cut the pip ● Confirm the pipe length according to the distance of indoor unit and outdoor unit. ●...
Service Manual Appendix 4: List of Resistance for Temperature Sensor Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units(15K) Temp( C) Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( Resistance(kΩ) 138.1 18.75 3.848 1.071 128.6 17.93 3.711 1.039 121.6 17.14 3.579 1.009...
Page 95
Service Manual Resistance Table of Tube Temperature Sensors for Indoor and Outdoor (20K) Temp( C) Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( Resistance(kΩ) 181.4 25.01 5.13 1.427 171.4 23.9 4.948 1.386 162.1 22.85 4.773 1.346 153.3 21.85 4.605 1.307 20.9 4.443 1.269 137.2...
Page 96
Service Manual Resistance Table of Discharge Temperature Sensor for Outdoor(50K) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) 853.5 18.34 4.75 799.8 93.42 17.65 4.61 89.07 16.99 4.47 703.8 84.95 16.36 4.33 660.8 81.05 15.75 4.20 620.8 77.35 15.17 4.08 580.6...
Page 97
GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 Email: gree@gree.com.cn Http://www.gree.com HONG KONG GREE ELECTRIC APPLIANCES SALES LIMITED Add: Unit 2612,26/F.,Miramar Tower 132 Nathan Road,TST,Kowloon,HK Tel: (852) 31658898 Fax: (852) 31651029...