Figure 9
1
G
B
H
J
C
4
L
J
1 – Installation of Ø120mm diameter
A
chimney with space around the pipe
(B):
min 100 mm, if the pipe is near
non-flammable materials, such as
concrete, brick, and similar
min 300 mm, if the pipe is near
flammable materials, such as wood
and similar
In both cases, appropriate insulation
between the chimney and the ceiling
is necessary
2 – Existing chimney; minimum smoke
venting pipe diameter Ø 80mm with
external chimney inspection and
cleaning hatch
3 – External chimney made of
insulated stainless steel pipes,
Ø80mm minimum diameter. The
entire construction must be safely
3
installed onto the wall and must have
a protective cap on top (see chapter
4.5.4.)
4 – Smoke venting system with T-
pieces enabling easier access when
cleaning the chimney without the
necessity of deconstructing the pipes.
A – see figure 15 and chapter 4.5.4.
J
B – space around the chimney pipe
C – minimum 500 mm
G
D – maximum 3 m
E – minimum 50 mm
J
F – minimum 3°
G – insulation
H – reduction from Ø80 to Ø100 mm
J – maintenance and cleaning
opening
K – maintenance and cleaning hatch
L – T-piece with maintenance and
cleaning opening
M – fresh external air supply grid