Figure 9
1
G
B
H
J
C
4
L
J
1 – Installation of Ø120mm diameter
A
chimney with space around the pipe
(B):
 min 100 mm, if the pipe is near
non-flammable materials, such as
concrete, brick, and similar
 min 300 mm, if the pipe is near
flammable materials, such as wood
and similar
In both cases, appropriate insulation
between the chimney and the ceiling
is necessary
2 – Existing chimney; minimum smoke
venting pipe diameter Ø 80mm with
external chimney inspection and
cleaning hatch
3 – External chimney made of
insulated stainless steel pipes,
Ø80mm minimum diameter. The
entire construction must be safely
3
installed onto the wall and must have
a protective cap on top (see chapter
4.5.4.)
4 – Smoke venting system with T-
pieces enabling easier access when
cleaning the chimney without the
necessity of deconstructing the pipes.
A – see figure 15 and chapter 4.5.4.
J
B – space around the chimney pipe
C – minimum 500 mm
G
D – maximum 3 m
E – minimum 50 mm
J
F – minimum 3°
G – insulation
H – reduction from Ø80 to Ø100 mm
J – maintenance and cleaning
opening
K – maintenance and cleaning hatch
L – T-piece with maintenance and
cleaning opening
M – fresh external air supply grid