SENKO SN-EN-08 Instruction Manual

Central heating fireplaces

Advertisement

Quick Links

Central heating
FIREPLACES
Central 20 -25 kW, Central 30 -35 kW
SN-EN-08/13

Advertisement

Table of Contents
loading

Summary of Contents for SENKO SN-EN-08

  • Page 1 Central heating FIREPLACES Central 20 -25 kW, Central 30 -35 kW SN-EN-08/13...
  • Page 2 Dear client, thank you for choosing a SENKO fireplace ! This product was designed and manufactured to its minutest details in order to fulfill your every need for functionality and safety. This Instruction manual will teach you to operate your fireplace properly, so please read the manual carefully before using the fireplace.
  • Page 3: Table Of Contents

    ............25 4.5.2. INSTALLATION TESTING .......25 4.5.3. RECEIVING AND MAINTAINING THE INSTALLATION .................26 4.6. FIREPLACE LINING ..................26 4.6.1. LININGS ................26 4.6.2. AIR VENTS ..............26 4.6.3. DECORATIVE BEAMS ..............26 4.6.4. FIRE PROTECTION 5. HANDLING THE PRODUCT ...............28 SENKO fireplaces – Instruction manual...
  • Page 4 7.4. OLD FIREPLACE DISPOSAL .................36 7.5. SPARE PARTS 8. MALFUNCTIONS / CAUSES / SOLUTIONS ........36 9. TECHNICAL SUPPORT ..............38 10. TECHNICAL DATA ................39 11. TERMS OF WARRANTY ..............40 WARRANTY ....................41 INSTALLATION REPORT .................42 CE MARKING ....................43 SENKO fireplaces – Instruction manual...
  • Page 5: General

     E2284 Central 20-25 kW  E2285 Central 30-35 kW are models from the SENKO fireplaces palette which can accommodate your needs in the best possible way. Therefore, we ask you to CAREFULLY READ THESE INSTRUCTIONS, which will help you to achieve the best possible results already during the initial use.
  • Page 6: Fuel

     it is necessary to use protective heat insulated gloves when adding fuel to the firebox  protective heat insulated gloves must also be used when opening and closing firebox door and removing ash box. SENKO fireplaces – Instruction manual...
  • Page 7: Chimney

     constructed to prevent rain, snow, leaves and other foreign bodies from entering the chimney,  constructed to enable expulsion of combustion products in case of wind from any direction and incline, SENKO fireplaces – Instruction manual...
  • Page 8 1,3 m from the roof < 1,3 0,5 m above the roof ridge 45° > 1,3 2 m from the roof < 1,2 0,5 m above the roof ridge 60° > 1,2 2,6 m from the roof SENKO fireplaces – Instruction manual...
  • Page 9: Chimney Function

    17 Pa Favorable Unfavorable position position Horizontal wind 8 m/s  underpressure of 30 Pa wind High (positive) Low (negative) pressure zone pressure zone Flue   gases OVERPRESSURE UNDERPRESSURE figure 2 from the fireplace SENKO fireplaces – Instruction manual...
  • Page 10 (A). Contrary to that, underpressure can occur in lee rooms (C), adversely affecting functions of the chimney situated on the opposite side (D) from the wind direction. descending wind figure 3 wind zones in overpressure zones in underpressure SENKO fireplaces – Instruction manual...
  • Page 11: Insulation

    A fireplace shall not be mounted in the following places:  staircase (allowed in apartment buildings with less than two apartments),  hallways,  rooms with highly explosive and flammable substances and materials or mixtures which can represent a potential flammable risk, SENKO fireplaces – Instruction manual...
  • Page 12: Technical Features

    3. TECHNICAL FEATURES SENKO fireplaces are made of quality boiler metal sheets. The water container is located at the rear, on the sides and at the top. This is why SENKO fireplaces have a high efficiency rate and can be mounted combined with any other heating system.
  • Page 13 22. Opening for secondary air circulation thermal protection needed for firebox glass door Secondary air inlet cleaning Primary air inlet 10. Room heating tubes 11. Dome 12. Chimney connection point extension 13. Door handle 14. Primary air automatic regulator handle SENKO fireplaces – Instruction manual...
  • Page 14 22. Opening for secondary air circulation thermal protection needed for firebox glass door Secondary air inlet cleaning Primary air inlet 10. Room heating tubes 11. Dome 12. Chimney connection point extension 13. Door handle 14. Primary air automatic regulator handle SENKO fireplaces – Instruction manual...
  • Page 15: Installation

    60 mm non-inflammable insulation layer. The layer has to reach 800 mm in front of the fireplace and 400 mm away in other directions (Figure 6). SENKO fireplaces – Instruction manual...
  • Page 16 6 range of firebox door opening SENKO fireplaces – Instruction manual...
  • Page 17: Chimney Preparation And Control

    Smoke outlet pipe must not penetrate into the chimney clear opening (figure 7c). Differences between the proper and improper connection of the fireplace to the chimney are displayed in the following figure. SENKO fireplaces – Instruction manual...
  • Page 18 IMPROPER PROPER figure 7 SENKO fireplaces – Instruction manual...
  • Page 19: Fresh Air Vents

    This prevents boiler overheating, system noise, pump malfunctions and mixing valve malfunctions. The connection to the heating system is executed via union flat joint, with or without the mixing valve onto an open or closed system SENKO fireplaces – Instruction manual...
  • Page 20 It is necessary to install the deaerating valve. When filling the boiler and the radiator system it is necessary to open the mixing valve, if one had been installed; adequately deaerate the boiler and the heating system. SENKO fireplaces – Instruction manual...
  • Page 21: Fireplace Thermal Protection

    The central heating system must have its own separate thermo- manometer ! Orientation schematic for connecting fireplace to a central heating system are shown in the following figures. Schemes shown are for guidance only and do not have the project value ! SENKO fireplaces – Instruction manual...
  • Page 22: Thermal Two-Way Safety Valve

    4.5.1.1. THERMAL TWO-WAY SAFETY VALVE SENKO fireplaces – Instruction manual...
  • Page 23: Thermal Safety Valve

    4.5.1.2. THERMAL SAFETY VALVE SENKO fireplaces – Instruction manual...
  • Page 24: Anti-Freezing Protection

    4.5.1.3. ANTI-FREEZING PROTECTION SENKO fireplaces – Instruction manual...
  • Page 25: Heat Exchanger

    4.5.1.4. HEAT EXCHANGER SENKO fireplaces – Instruction manual...
  • Page 26: Installation Testing

    This will ensure safe working performance of the boiler, as well as economic and immaculate heating. In case of installation faulty operation, contact your central heating installation contractor exclusively ! SENKO fireplaces – Instruction manual...
  • Page 27: Fireplace Lining

    After mounting the proper chimney attachment you need to carry out pre-masonry work and insulate the area around the fireplace against heat. You need to ensure a 800 mm safety distance in front of the fireplace and on the sides (see (26) Figure 13). SENKO fireplaces – Instruction manual...
  • Page 28 20. Hot air outlet grate 21. Tubes for room heating air-through (free or forced circulation) 22. Flue damper handle 23. Linings 24. Bearing element 25. 60 mm heating insulation layer 26. 800 mm irradiation area figure 13 SENKO fireplaces – Instruction manual...
  • Page 29: Handling The Product

    Secondary air connection point (8) is located on the back side of the fireplace in the connection with the primary air inlet (9). SENKO fireplaces – Instruction manual...
  • Page 30: Firing

    Primary air volume and chimney flue draught must be adjusted to levels that prevent boiler water temperature from exceeding 85C. Maximum quantity of fuel that can be accommodated in the firebox:  6 kg for Central 20-25 kW,  8 kg for Central 30-35 kW. SENKO fireplaces – Instruction manual...
  • Page 31: Adding Fuel

    (approx. 1 cm thick). Primary air automatic regulator must be completely closed at least ten seconds before opening the firebox door to prevent the breach of flue gases into the residential area. SENKO fireplaces – Instruction manual...
  • Page 32: Feeding In Transition Period

    5.2.5. SPACE HEATING Tubes (10) are embedded in the dome (11), through which passes the air for space heating. Air can circulate natural and can also forcibly, installing the fan and routers. SENKO fireplaces – Instruction manual...
  • Page 33: Cleaning

    We recommend cleaning with non-inflammable agents like those for cleaning grills or ovens or our own SENKO soot and grease cleaning agent. The agent is supplied to you together with the fireplace ! Best way to clean the glass is while it is cold →...
  • Page 34: Ash Cleaning

    ! 6.3. CHIMNEY CLEANING For your safety, you should consider cleaning of the chimney at least once in a year. Cleaning shall be carried out by a qualified chimney-sweeper ! SENKO fireplaces – Instruction manual...
  • Page 35: Maintenance

    – Figure 15e and f,  loosen 4 M6 bolts with a wrench – Figure 15g and h,  remove and change the automatic regulator. SENKO fireplaces – Instruction manual...
  • Page 36  installation of a new regulator is executed by reversing the procedure, provided that the probe capillary SENKO fireplaces – Instruction manual must not have an angle equalling or exceeding 90 at any point, and all transitions must be executed...
  • Page 37: Old Fireplace Disposal

    There is noise from the  execute the central heating pressure in the central boiler installation in accordance with heating system  improper central professional standards and DIN 4751 norm - part 1 for open systems, i.e. heating installation SENKO fireplaces – Instruction manual...
  • Page 38 4.2. Temperature in firebox  reduce primary air volume draught too low  excessive primary  use fuel as described in chapter 1.1.  add less fuel to the firebox air volume SENKO fireplaces – Instruction manual...
  • Page 39: Technical Support

     warranty (at the back of this Manual),  written installation report (at the back of this Manual),  Instruction manual. The documents listed above are necessary to ensure the quickest and clearest removal of the occurring malfunction. SENKO fireplaces – Instruction manual...
  • Page 40: Technical Data

    The manufacturer withholds the right to change any technical specification to further improve the products SENKO fireplaces – Instruction manual...
  • Page 41: Terms Of Warranty

    SENKO fireplaces – Instruction manual The manufacturer SENKO d.o.o. withholds the right to alter any technical details, data and photographs published in this booklet without prior warning, for the purpose of improving its products. Photographs of the fireplace, parts, elements and equipment...
  • Page 42: Warranty

    WARRANTY WARRANTY No. SOLID FUEL CENTRAL HEATING FIREPLACE : E2284 Central 20-25 kW E2285 Central 30-35 kW SERIAL NUMBER: _________________________________ DATE OF MANUFACTURE: ______________________________ STORE NAME _____________________________________ AND ADDRESS: _____________________________________ CLIENT NAME _____________________________________ AND ADDRESS: _____________________________________ DATE OF PURCHASE: __________________________________ STORE STAMP AND DEALER SIGNATURE: __________________________________...
  • Page 43: Installation Report

    Heated space volume (m ): ………… Expansion tank volume (m Pump type: …………….. Water flow (m /h): …………… Safety valve type: …………….. Safety valve approved at …….bar SENKO kamini – Uputstvo za upotrebu Water temperature (°C)  inlet: ……….  outlet: ..
  • Page 44: Ce Marking

    Manufactured in the Republic of Croatia. DECLARATION OF CONFORMITY This product is certified in accordance with the EN 13229. Test report number 30-11665/5 from June 29 , 2012. SENKO kamini – Uputstvo za upotrebu The original product Certificate and Declaration of Conformity available upon request.
  • Page 45 NOTES : ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ SENKO kamini – Uputstvo za upotrebu...
  • Page 46 SENKO kamini – Uputstvo za upotrebu...
  • Page 47 SENKO kamini – Uputstvo za upotrebu...
  • Page 48 A HEALTHY ENVIRONMENT. You can find this Manual at http://en.senko.hr/ If you have any suggestions on how to improve this Manual or you have noticed any deficiency, feel free to contact us on tehnologija@senko.hr SN-EN-08/13 SENKO kamini – Uputstvo za upotrebu...

This manual is also suitable for:

Sn-en-13E2284 central 20-25 kwE2285 central 30-35 kw

Table of Contents