Central heating FIREPLACES Central 20 -25 kW, Central 30 -35 kW SN-EN-08/13...
Page 2
Dear client, thank you for choosing a SENKO fireplace ! This product was designed and manufactured to its minutest details in order to fulfill your every need for functionality and safety. This Instruction manual will teach you to operate your fireplace properly, so please read the manual carefully before using the fireplace.
E2284 Central 20-25 kW E2285 Central 30-35 kW are models from the SENKO fireplaces palette which can accommodate your needs in the best possible way. Therefore, we ask you to CAREFULLY READ THESE INSTRUCTIONS, which will help you to achieve the best possible results already during the initial use.
it is necessary to use protective heat insulated gloves when adding fuel to the firebox protective heat insulated gloves must also be used when opening and closing firebox door and removing ash box. SENKO fireplaces – Instruction manual...
constructed to prevent rain, snow, leaves and other foreign bodies from entering the chimney, constructed to enable expulsion of combustion products in case of wind from any direction and incline, SENKO fireplaces – Instruction manual...
Page 8
1,3 m from the roof < 1,3 0,5 m above the roof ridge 45° > 1,3 2 m from the roof < 1,2 0,5 m above the roof ridge 60° > 1,2 2,6 m from the roof SENKO fireplaces – Instruction manual...
17 Pa Favorable Unfavorable position position Horizontal wind 8 m/s underpressure of 30 Pa wind High (positive) Low (negative) pressure zone pressure zone Flue gases OVERPRESSURE UNDERPRESSURE figure 2 from the fireplace SENKO fireplaces – Instruction manual...
Page 10
(A). Contrary to that, underpressure can occur in lee rooms (C), adversely affecting functions of the chimney situated on the opposite side (D) from the wind direction. descending wind figure 3 wind zones in overpressure zones in underpressure SENKO fireplaces – Instruction manual...
A fireplace shall not be mounted in the following places: staircase (allowed in apartment buildings with less than two apartments), hallways, rooms with highly explosive and flammable substances and materials or mixtures which can represent a potential flammable risk, SENKO fireplaces – Instruction manual...
3. TECHNICAL FEATURES SENKO fireplaces are made of quality boiler metal sheets. The water container is located at the rear, on the sides and at the top. This is why SENKO fireplaces have a high efficiency rate and can be mounted combined with any other heating system.
Page 13
22. Opening for secondary air circulation thermal protection needed for firebox glass door Secondary air inlet cleaning Primary air inlet 10. Room heating tubes 11. Dome 12. Chimney connection point extension 13. Door handle 14. Primary air automatic regulator handle SENKO fireplaces – Instruction manual...
Page 14
22. Opening for secondary air circulation thermal protection needed for firebox glass door Secondary air inlet cleaning Primary air inlet 10. Room heating tubes 11. Dome 12. Chimney connection point extension 13. Door handle 14. Primary air automatic regulator handle SENKO fireplaces – Instruction manual...
60 mm non-inflammable insulation layer. The layer has to reach 800 mm in front of the fireplace and 400 mm away in other directions (Figure 6). SENKO fireplaces – Instruction manual...
Page 16
6 range of firebox door opening SENKO fireplaces – Instruction manual...
Smoke outlet pipe must not penetrate into the chimney clear opening (figure 7c). Differences between the proper and improper connection of the fireplace to the chimney are displayed in the following figure. SENKO fireplaces – Instruction manual...
This prevents boiler overheating, system noise, pump malfunctions and mixing valve malfunctions. The connection to the heating system is executed via union flat joint, with or without the mixing valve onto an open or closed system SENKO fireplaces – Instruction manual...
Page 20
It is necessary to install the deaerating valve. When filling the boiler and the radiator system it is necessary to open the mixing valve, if one had been installed; adequately deaerate the boiler and the heating system. SENKO fireplaces – Instruction manual...
The central heating system must have its own separate thermo- manometer ! Orientation schematic for connecting fireplace to a central heating system are shown in the following figures. Schemes shown are for guidance only and do not have the project value ! SENKO fireplaces – Instruction manual...
This will ensure safe working performance of the boiler, as well as economic and immaculate heating. In case of installation faulty operation, contact your central heating installation contractor exclusively ! SENKO fireplaces – Instruction manual...
After mounting the proper chimney attachment you need to carry out pre-masonry work and insulate the area around the fireplace against heat. You need to ensure a 800 mm safety distance in front of the fireplace and on the sides (see (26) Figure 13). SENKO fireplaces – Instruction manual...
Page 28
20. Hot air outlet grate 21. Tubes for room heating air-through (free or forced circulation) 22. Flue damper handle 23. Linings 24. Bearing element 25. 60 mm heating insulation layer 26. 800 mm irradiation area figure 13 SENKO fireplaces – Instruction manual...
Secondary air connection point (8) is located on the back side of the fireplace in the connection with the primary air inlet (9). SENKO fireplaces – Instruction manual...
Primary air volume and chimney flue draught must be adjusted to levels that prevent boiler water temperature from exceeding 85C. Maximum quantity of fuel that can be accommodated in the firebox: 6 kg for Central 20-25 kW, 8 kg for Central 30-35 kW. SENKO fireplaces – Instruction manual...
(approx. 1 cm thick). Primary air automatic regulator must be completely closed at least ten seconds before opening the firebox door to prevent the breach of flue gases into the residential area. SENKO fireplaces – Instruction manual...
5.2.5. SPACE HEATING Tubes (10) are embedded in the dome (11), through which passes the air for space heating. Air can circulate natural and can also forcibly, installing the fan and routers. SENKO fireplaces – Instruction manual...
We recommend cleaning with non-inflammable agents like those for cleaning grills or ovens or our own SENKO soot and grease cleaning agent. The agent is supplied to you together with the fireplace ! Best way to clean the glass is while it is cold →...
! 6.3. CHIMNEY CLEANING For your safety, you should consider cleaning of the chimney at least once in a year. Cleaning shall be carried out by a qualified chimney-sweeper ! SENKO fireplaces – Instruction manual...
– Figure 15e and f, loosen 4 M6 bolts with a wrench – Figure 15g and h, remove and change the automatic regulator. SENKO fireplaces – Instruction manual...
Page 36
installation of a new regulator is executed by reversing the procedure, provided that the probe capillary SENKO fireplaces – Instruction manual must not have an angle equalling or exceeding 90 at any point, and all transitions must be executed...
There is noise from the execute the central heating pressure in the central boiler installation in accordance with heating system improper central professional standards and DIN 4751 norm - part 1 for open systems, i.e. heating installation SENKO fireplaces – Instruction manual...
Page 38
4.2. Temperature in firebox reduce primary air volume draught too low excessive primary use fuel as described in chapter 1.1. add less fuel to the firebox air volume SENKO fireplaces – Instruction manual...
warranty (at the back of this Manual), written installation report (at the back of this Manual), Instruction manual. The documents listed above are necessary to ensure the quickest and clearest removal of the occurring malfunction. SENKO fireplaces – Instruction manual...
SENKO fireplaces – Instruction manual The manufacturer SENKO d.o.o. withholds the right to alter any technical details, data and photographs published in this booklet without prior warning, for the purpose of improving its products. Photographs of the fireplace, parts, elements and equipment...
WARRANTY WARRANTY No. SOLID FUEL CENTRAL HEATING FIREPLACE : E2284 Central 20-25 kW E2285 Central 30-35 kW SERIAL NUMBER: _________________________________ DATE OF MANUFACTURE: ______________________________ STORE NAME _____________________________________ AND ADDRESS: _____________________________________ CLIENT NAME _____________________________________ AND ADDRESS: _____________________________________ DATE OF PURCHASE: __________________________________ STORE STAMP AND DEALER SIGNATURE: __________________________________...
Manufactured in the Republic of Croatia. DECLARATION OF CONFORMITY This product is certified in accordance with the EN 13229. Test report number 30-11665/5 from June 29 , 2012. SENKO kamini – Uputstvo za upotrebu The original product Certificate and Declaration of Conformity available upon request.
Page 48
A HEALTHY ENVIRONMENT. You can find this Manual at http://en.senko.hr/ If you have any suggestions on how to improve this Manual or you have noticed any deficiency, feel free to contact us on tehnologija@senko.hr SN-EN-08/13 SENKO kamini – Uputstvo za upotrebu...