Air may also be supplied from adjoining rooms (figure 6b). It is
important that these rooms are in constant free supply of external air.
Adjoining room must meet all the criteria listed above with regard to the
installation room and must not be used as a bedroom, bathroom or any
space where fire may occur (e.g. garage, woodshed, flammable material
storage room and similar).
A
Figure 7
SENKO pellet AIR stoves – Instruction manual
Figure 6
minimum
2
100 cm
air passage
under the door
If the air necessary for
combustion is sucked via
pipes
directly
external
environment,
round
pipe
downward incline must be
installed outside, equipped
with a protective grid, due to
birds and potential accidental
clogging.
B
fresh air intake
from the outside
from
the
a
in
a
90°
16