C. Blower (Optional)
1. Remove the 3 bolts (1/4"-20 Phillips head) on the outer
skin at the bottom rear of appliance.
2. Align holes in mounting fl ange of blower with bolt holes in
appliance. Blower should be positioned at bottom of rear
outer skin as shown in Figure 15.1.
3. Re-insert and tighten bolts, securing blower onto outer
wall of appliance.
4. Place the bracket containing the snap disc and magnet
under the bottom left rear corner as shown in Figure 15.1.
See page 30 for detailed operating instructions for the
blower and snap disc.
Figure 15.1
Figure 15.2
August 3, 2015
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance..
NOTE: The blower cord is equipped with a 3 pronged
(grounding) plug for your protection against shock hazard.
Do not remove.