NORPOLE EW CIM65S User Manual page 28

Automatic ice maker
Table of Contents

Advertisement

Prob l em
A few water drops fall to
the floor when you open the
door to take out ice from
ice storage bin.
Water supply connection
Water is leaking
leaking.
from the unit.
Nut of water drain hole
leaking.
Drain hose connection
leaking.
Cubes are partially
formed or are
Not enough water in the
white at the
water sump.
bottom.
The ice cubes are
incomplete when
The sprinkler is blocked.
being dumped.
The feet are not leveled and
Noise during
locked.
operation
Certain sounds are normal. See " Normal Sounds".
The electricity is off.
The ice maker
The room temperature is
stops suddenly
out of the stated range.
while making ice.
The ventilation louvers are
covered.
The body of the
The grounding line isn't in
ice maker is
the socket.
electrified.
Scale occurs
The hardness of the water is
frequently inside
too high.
the machine.
Possib l e Cause
27
Prob ab l e Correction
Normal condensation on the door or
some water together with ice. Take
care when you take out ice.
Tighten fitting. See " Connecting the
Water Line".
Tighten the nut.
Tighten fitting. See " Connecting the
Drain".
Check if the water supply pressure is
below 2 0 psig.
Check water supply; filter may be
restricted.
Check for a water leak at the water sump.
Check if water inlet valve is restricted.
Clean it; see "Interior Cleaning".
Level and lock the feet. See "Leveling
the Ice Maker".
Reconnect the power supply line.
Cut off the electricity; let the ice maker
stop working till the temperature
returns within the stated range.
Remove the obstruction.
Use a socket meeting the required
electrical standard.
Use a water-softening device installed
in front of the water inlet valve.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ew cim90sEw cim120s

Table of Contents