ENGINE PROTECTION (ES - EV)
The devices ES or EV ensure the protection of the
engine in case of low oil pressure or engine high
temperature.
The system consist of electronic card of control
and check, and of an engine stop device: solenoid
(ElettroStop), electrovalve (ElettroValvola)
The device enter in operation when the engine
starts and, in case of low oil pressure and high
temperature, will stop the machine and show the
cause of the stop with the warning light of high
temperature or low oil pressure.
In case of low oil pressure, check the level and if it
is correct, call the Service Station. In case of high
temperature, make sure that there are no leaves
and/or pieces of material obstructing the air ducts.
N.B.: if the unit is used as a generator in hot
climates and with loads near to the maximum,
the protection device can be triggered off, please
reduce the load of the engine.
Once the cause of the problem is removed, to reset
the protection, it is enough to report the ignition key
(Q1) on "OFF" position and start the engine again.
USE OF THE PROTECTION
ENGINE PROTECTION
ES - EV
!
NOTE
THE ENGINE PROTECTIONS DO NOT WORK WHEN
THE OIL IS OF LOW QUALITY BECAUSE NOT CHANGED
REGULARLY AT INTERVALS AS PRESCRIBED IN THE
OWNER’S ENGINE MANUAL.
M
39.4
High temperature
Low oil pressure