CONTENTS SAFETY................1 Safety Label Location................1 Safety Information..................2 II. INTRODUCTION ................. 4 III. OPERATION..................6 1. Generator Use ................6 2. Pre-Operation Check..............7 1) Engine oil................. 7 2) Fuel..................8 3. Operation..................10 1) Starting the engine..............10 2) Stopping the engine...............
Page 4
Thank you for purchasing our generator. at the time of printing. This manual should be considered a permanent part of the generator and should READ THIS OWNER’S MANUAL CAREFULLY. Pay special attention to these NOTE: Gives helpful information. WARNING SYMBOLS DANGER Indicates a strong possibility that serious injury or death could result if WARNING...
GENERATOR SAFETY Safety Information safe operating procedures. 1. Operator Responsibility • • Understand the use of all generator controls, output receptacles, and connections. • • Exhaust contains poisonous carbon monoxide, a colorless and odorless gas. Breathing exhaust can cause loss of consciousness and may lead to death. •...
Page 7
GENERATOR SAFETY • System ground The generator has a system ground that connects the generator frame components to the properly from this generator. Safety Information • The exhaust system gets hot enough to ignite some materials. operation. Do not enclose the generator in any structure. the generator indoors.
INTRODUCTION AC CIRCUIT BREAKER GENERATOR SWITCH AIR FILTER AC RECEPTACLES FUEL VALVE DC TERMINAL POSTS RECOIL STARTER FUEL TANK CAP FUEL METER MUFFLER...
Page 9
INTRODUCTION GE 3900 GE 6900 Model Rated Output (kW) Max Output (kW) Rated Voltage (V) Fuel tank Capacity (l) DC Output (V/ A) 12/8.3 Phase Single Sigle Noise dB(A) (7m) Engine model Forced air-cooling, Forced air-cooling, Engine type 4-stroke, OHV...
OPERATIONS Generator Use b. Unplug all loads from the Generator. c. Inspect the Generator and engine. 3. Plug in products. NOTICE Under normal operating conditions subsequent maintenance follows the schedule explai- ned in the SERVICE section.
OPERATIONS Pre-operation Check 1. Engine Oil NOTICE ne stopped. Use 4-stroke motor oil that meets SERVICE label on the oil container to be sure it includes the letters SF or SG.
OPERATIONS 2. Fuel WARNING sure the tank cap is closed properly and securely. spilled, make sure the area is dry before starting the engine. • KEEP OUT OF REACH OF CHILDREN. Fuel Tank capacity GE 3900 GE 6900 20 l...
Page 13
OPERATIONS operate on unleaded gasoline. life. the fuel tank. If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of...
OPERATIONS Starting The Engine Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. tion. Pull the starter grip lightly until resistance is felt, then pull briskly. NOTICE...
TRANSPORTING & STORAGE When the equipment is to remain idle for longer than 20 days, prepare the engine for storage as NOTICE A. Change engine oil. oil into cylinder through spark plug hole. Before starting the Engine during or after storage, keep in mind that untreated gasoline recommended time period, or if the engine does not start.
SERVICE Engine Oil capacity GE 3900 0.6 l GE 6900 1.1 l NOTICE 3) Air Filter Element Maintenance areas.
Page 19
SERVICE NOTICE 2. Wash the element in a solution of 3. Soak the element in clean engine oil and much oil is left in the element. 4. Reinstall the air cleaner element and the 4) Fuel Sediment Cup Cleaning carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. c) Reinstall the O-ring and sediment cup.
Page 20
SERVICE Recommended spark plugs: GE 3900 F6(R)TC - F7(R)TC GE 6900 To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 2. Clean any dirt from around the spark plug base. 4. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped.
SERVICE Troubleshooting Is there fuel in the tank? Is there enough oil in the Add the recommended oil engine? Still NO Take the generator Is there a spark from the Replace the spark spark plug? spark plug generator dealer Is the fuel reaching Check and clean the fuel the carburetor? sediment cup...
Page 30
INDICE SICUREZZA DEL ............1 Posizione dell’etichetta di sicurezza ............1 Informazioni sulla sicurezza ..............2 II. INTRODUZIONE ................. 4 III. OPERAZIONE..................6 1. Uso del generatore ................. 6 2) Carburante ................8 3. Funzionamento ................10 1) Avviamento del motore............10 2) Arresto del motore..............
Page 31
Grazie per aver acquistato il nostro generatore. Questo manuale riguarda il funzionamento e la manutenzione del nostro generatore. generatore se viene rivenduto. NOTA: Fornisce informazioni utili. SIMBOLI DI AVVERTENZA ( AVVISO) Indica lesioni gravi o morte se non vengono seguite le istruzioni. DANGER WARNING seguite le istruzioni.
SICUREZZA DEL GENERATORE Informazioni sulla sicurezza • • • 2. Pericoli di monossido di carbonio • • 3. Rischi di scosse elettriche • • •...
Page 34
SICUREZZA DEL GENERATORE • Messa a terra del sistema 4. Pericoli di incendio e ustione il funzionamento. Non racchiudere il generatore in nessuna struttura.
OPERAZIONI Uso del generatore b. Scollegare tutti i carichi dal generatore. autorizzate. NOTICE In condizioni di normale funzionamento la successiva manutenzione segue il programma spiegato nella sezione SERVICE.
Page 38
OPERAZIONI Controllo pre-operazione 1. Olio motore NOTA cazione del servizio API SF o SG. Controllare SF o SG. vallo indicato. LIVELLO MASSIMO TAPPO RIEMPIMENTO OLIO FORO RIEMPIMENTO TAPPO RIEMPIMENTO OLIO OLIO...
Fare attenzione a non versare carburante durante il rifornimento. Il carburante versato o i Capacità serbatoio GE 3900 GE 6900 20 l CHIUSO...
Page 40
OPERAZIONI durata del sistema di scarico. Non utilizzare mai benzina vecchia o contaminata o miscele di olio/benzina. Evitare di far entrare rivenditore autorizzato di generatori.
TRASPORTO E STOCCAGGIO NOTA carburante. Non fumare. A. Cambiare l’olio motore. B. Pulire l’area intorno alla candela. Rimuovere la candela e versare un cucchiaio di olio motore nel cilindro attraverso il foro della candela. resistenza). non si avvia.
SERVIZIO Manutenzione 1) Programma di manutenzione Programma di Manutenzione OGGETTO PERIODO Ogni uso 20 h 50 h 100 h 300 h Controllo livello Olio motore Cambio Controllo Filtro aira Pulizia Sedimenti Pulizia Candela Sostituzione Pulizia Gioco valvole Pulizia carburante Circuito carburante Controllare Ogni 2 anni 2) Cambio olio motore...
Page 45
SERVIZIO Capacità olio motore GE 3900 0.6 l GE 6900 1.1 l NOTA LIVELLO MASSIMO TAPPO SCARICO OLIO TAPPO SCARICO OLIO...
Page 46
SERVIZIO NOTA COPERCHIO FILTRO ARIA ELEMENTO FILTRO ARIA ELEMENTO...
Page 47
SERVIZIO COPPA SEDIMENTI Candele raccomandate: GE 3900 GE 6900 silenziatore. CHIAVE PER CANDELA candela. CAPPUCCIO CANDELA scheggiato. Pulisci la candela con una riusata. laterale.
Page 48
SERVIZIO Ricerca guasti Rifornire il serbatoio Aggiungere l’olio raccomandato Ancora nessuna Porta il generatore Sostituire la scintilla da un rivenditore candela autorizzato Il carburante arriva rivenditore autorizzato Porta il generatore da un rivenditore autorizzato eventualmente difettosi...