Calibration procedure:
1) Remove the safety key
2) Press and hold down the INCLINE and SPEED buttons with one hand and replace the safety
key with the other. Continue to hold both keys until the window displays "FACTORY SETTING",
then press the ENTER key.
3) You will now be able to set the display to show Metric or English settings. To do this, press
UP/DOWN or FAST/SLOW keys to show which you want, then press ENTER.
4) Make sure the wheel size diameter is 2.98 then press ENTER.
5) Adjust the maximum speed (if needed) to 20.0kph or 12.0 mph and then press ENTER.
6) Adjust the minimum speed (if needed) to 0.8kph or 0.5 mph and then press ENTER.
7) Message Windows will show "INCLINE STEPS ". Adjust the maximum elevation (if needed) to
15 and then press ENTER.
8) Message Windows will show "CALIBRATION ON". Press START to begin calibration. The
process is automatic; the speed will start up without warning, so do not stand on the belt.
After finishing calibration, it automatically returns to IDLE MODE.
Adjusting the speed sensor:
If the calibration does not pass you may need to check the speed sensor alignment.
1) Release motor cover screws (screws are not necessarily taken apart) and remove the motor
cover hood.
2) The speed sensor is located on the left side of the frame, right next to the front roller pulley (the
pulley will have a belt around it that also goes to the motor). The speed sensor is small and
black square with a wire connected to it.
3) Make sure the sensor is as close as possible to the pulley without touching it. You will see a
magnet on the face of the pulley; make sure the sensor is aligned with the magnet. There is a
screw that holds the sensor in place that needs to be loosened to adjust the sensor. Re-tighten
the screw when finished.
Resetting cumulated distance and time (DIAGNOSTICS PROCESS):
1) Remove the safety key and press numeric key 0 and ENTER then return the safety key to
enter displaying the version of cumulated distance and time. Total time is shown on window
TIME while total mileage and software version on window MW.
2) To clear the value, press numeric keys 7 → 8 → 9 → 7 hen press ENTER key to reset
total mileage and time to zero.
3) Press STOP key to exit and return idle mode.
CUSTOMER SERVICE 1-888-707-1880
EMAIL:
customerservice@dyaco.ca