9.Fault Clearing
9.1.3.

Fault Status LED

9.1.3.1. Fault status LED is on during operation

Hardware error detected (on); ServerView detected a fault (blinking), check ServerView for service action.
9.1.4.

Storage Subsystem Switches OFF

Temperature too high
The temperature sensors have measured an extreme temperature (tolerable temperature for operation
section "
see
Technical Data
Wait until the storage subsystem has cooled down.
9.1.5.

System does not Start Up after New Drives have been Installed

SAS configuration incorrect (RAID controller)
Call up the configuration menu and check the drive settings (device configuration) and the additional
settings (advanced configuration options).
9.1.6.

Ready LED of the Hard Disk Drive does not Come ON

Check whether the hard disk drive has been correctly installed and locked (see
"
Removing/Installing Hard Disk Drive/Blank Insert
Hard disk drive or backplane is defective
Replace the hard disk drive. If the ready LED is still OFF, the backplane is defective. Contact the
service organization.
" on page
5) and the server has shut down the system.
" on page
21).