Disconnect the SC100/SC120 Expansion Enclosure from the B-Side of the
Chain
Disconnect the B-side cables from the expansion enclosure that you want to remove.
1.
Disconnect the B-side cable (shown in blue) from expansion enclosure 1: bottom EMM, port A. The
A-side cables continue to carry IO while the B-side is disconnected.
2.
Remove the B-side cable between expansion enclosure 1: bottom EMM, port B and expansion
enclosure 2: bottom EMM, port A.
Adding or Removing an Expansion Enclosure
2.
Storage controller 1
4.
Expansion enclosure 1