Pentair pool products heat pump brochure (2 pages)
Summary of Contents for Pentair XLHP
Page 1
AQUATIC ECO-SYSTEMS™ XLHP ™ HIGH PERFORMANCE HEAT PUMP INSTALLATION AND USER'S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...
CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions about ordering Pentair Aquatic Eco-Systems replacement parts, and products, please use the following contact information: Customer Service Web site 8 AM to 7 PM — Eastern and Pacific Times Visit www.pentairaes.com...
For Electrical Supply and Voltage Requirements, refer to the table Codes and Standards on page 20. XLHP heat pumps are listed by ETL as complying with the latest edition of the “UL Standard for Safety for Heating and Cooling Equipment”, UL 1995 and CSA C22.2 No. 236.
Page 4
Menu appears only if a delay is active. T1- TANK1 REMOTE REV - REVERSING VALVE **** Menu appears only if defrost is enabled in the Service Menu. T2 - TANK2 REMOTE XLHP™ High Performance Heat Pump Installation and User's Guide...
BEFORE INSTALLING THE HEAT PUMP XLHP™ Heat Pump Overview General Features Your Pentair heat pump will provide you with years of • Dual digital thermostats offer precise temperature service and excellent performance. Heat pumps operate control to maintain the desired separate water...
When equipment is located below the water surface, a leak from any component can cause large scale water loss or flooding. Pentair Aquatic Eco-Systems, Inc. cannot be responsible for such water loss or flooding which may cause damage to property or to the product.
3. Install a minimum of 5 ft [1.52 m] from the body of The XLHP™ Heat Pump must be placed to provide water unless the heat pump is separated from the clearances on all sides for maintenance and inspection.
The image below shows the standard plumbing layout 4. Mark the position of the hole in each clamp on the with a single XLHP™ Heat Pump unit. Follow the image equipment pad. from right to left for the standard plumbing sequence.
SERVICE light is present then the water switch to close at too low of a flow can damage the appliance. Adjust the pressure switch needs to be adjusted. switch to turn the heater off, not on. XLHP™ High Performance Heat Pump Installation and User’s Guide...
Multiple Unit Installation Continued 1. Heat Pump, Heater and/or Solar Combination 4. Remove the XLHP™ Heat Pump’s left front panel In certain regions of the country it may be more and remove remaining right front panel. The water economical to run a heat pump during the warmer months pressure switch is located in the water plumbing in and a gas heater during the cooler months.
Page 11
120 GPM (456 lpm) Flow Meter Flow Meter 3" Ball Valve Bypass balancing Minimum To Body of Water Pump Minimum 3" PVC Pipe Four Heat Pump Plumbing Layout XLHP™ High Performance Heat Pump Installation and User’s Guide...
7. Replace the service panel and reinstall screws to hold it in place. 8. Replace the front left panel. 9. Connect a copper bonding wire (8 AWG) to the bonding lug on the left side of the heat pump. XLHP™ High Performance Heat Pump Installation and User’s Guide...
/RED PURPLE Compressor AutoSet Contactor Contactor BROWN PINK See Users Guide BLACK ORANGE for instructions on connecting to filter pump Incoming 230 VAC Power Connection GREEN LABEL P/N 473073 REV. E XLHP™ High Performance Heat Pump Installation and User’s Guide...
24 VAC THERM1 THERM2 POOL *Note: The XLHP heat pump has been tested and rated as an Aquaculture duty product, however, it is based ¼ in. “Spade” upon a heat pump product platform that is also used in connectors ( the swimming pool industry.
Energy Saving Tips Heat Pump Control Panel Overview It is important to note that a XLHP™ Heat Pump will not 1. ON/OFF button – Turns the heat pump On and Off. heat a body of water as fast as a large gas or electric 2.
Menu appears only if Defrost is enabled in the Service Menu. **** active. The active set point can be switched between TANK1 and TANK2 by using the UP and DOWN arrows. XLHP™ High Performance Heat Pump Installation and User’s Guide...
Relay Remote ACT= __ - Actual measured water temperature Note: The XLHP heat pump has been tested and rated as an 2. The screen automatically returns to the active aquaculture duty product, however, it is based upon a heat pump run screen after 15 seconds of keypad inactivity.
5. The heat pump will continue this cycle every time the water circulation pump is shut off. Note: The XLHP™ heat pump has been tested and rated 6. Once the time clock restarts the heat pump, the as an aquaculture duty product, however, it is based upon...
The heat pump’s green light will turn OFF and the heat pump will stay OFF when time expires. HEAT PUMP RUNTIME REMAINING = NONE XLHP™ High Performance Heat Pump Installation and User’s Guide...
Pressing the TANK1/TANK2 button while this screen PMP - FILTER PUMP when input/output is OFF. is displayed returns the display to the Tank 1 or Tank REV - REVERSING VALVE 2 Run Screen as appropriate. XLHP™ High Performance Heat Pump Installation and User’s Guide...
MENU SELECT and TANK1/TANK2 buttons Defrost Cycle simultaneously. Heat Pump The XLHP™ Heat Pump may enter a defrost cycle Control Panel if air temperatures are around 50°F (10°C). To enter a defrost cycle the Defrost feature must be enabled in the Operator Menus. Heat only pumps utilize a passive defrost cycle.
Check for leaks in and around the heat pump. 4. Turn on the electrical power to the heat pump at the main breaker panel. XLHP™ High Performance Heat Pump Installation and User’s Guide...
Call a qualified heat pump technician to investigate the problem. Typical Heating Cycle XLHP™ High Performance Heat Pump Installation and User’s Guide...
Troubleshoot Electrical Box. legs. A boost transformer may be needed closer to the heat pump to get voltages within proper range. Refer to 10K Ohm Temperature Resistance Chart on page 20. XLHP™ High Performance Heat Pump Installation and User’s Guide...
Page 27
1 hour or can be 5 alarms of any kind within one hour. again. This alarm most likely caused the five alarms in one manually reset by pressing the ON/OFF hour. button. XLHP™ High Performance Heat Pump Installation and User’s Guide...
Page 28
Call your dealer for advice. Call the factory for temperature. Air blower is running. Venturi air advice. inlets are open. It is very cold outside. Pump is not running. XLHP™ High Performance Heat Pump Installation and User’s Guide...
Page 29
Insufficient water flow, and Unit overcharged. Find source of refrigerant leak and fix. Pull vacuum and Low current with high superheat. Unit undercharged. charge. Unit runs, but breaker trips continuously. Electrical issue. Contact certified electrician. XLHP™ High Performance Heat Pump Installation and User’s Guide...
REPLACEMENT PARTS Illustrated Parts View DETAIL B DETAIL B *475 094* XLH P ™ HIGH PERF ORM ANCE HEAT PUM *475 092* XLHP™ High Performance Heat Pump Installation and User’s Guide...
Screw #10 x 1” Button Head Torx, Black Head 474321 3 IN Receiver [Not Shown] 474196 Panel, Front Left, w/ Decal, 36" Black 473054Z Coil Guard [Not Shown] 474193 HP Top, Black 473786 Guard, Fan XLHP™ High Performance Heat Pump Installation and User’s Guide...
Page 32
Pentair Aquatic Eco-Systems, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties.
Need help?
Do you have a question about the XLHP and is the answer not in the manual?
Questions and answers