SILENCING THE ALARM

1. In order to silence the alarm after it goes off, wipe the Moisture Sensor unit at the bottom of the
housing gently with a soft dry cloth in order to dry it off.
2. If this doesn't help, remove the alarm unit from the housing by gently sliding it out of its slot
(image #30).
3. Expose the white electrical plug under the black tape wrap (image #31).
4. Disconnect the electrical wires plug from the alarm unit socket.

REPLACING BATTERIES

1. Remove the alarm unit from the housing by gently sliding it
out of its slot (image #30).
2. Disconnect the electrical wires plug from the unit socket
(image #31).
3. Peel the black tape wrapped around the Alarm unit by gently
cutting it with a utility knife (image #32). Make sure that the
knife doesn't come in contact with the unit under
the tape and that you only cut the tape.
4. Remove the old battery by lifting it with a small
screwdriver through the battery removal groove
(image #33).
5. Prepare a new 3V Lithium #CR1220 battery, widely
available at any hardware store or watch repair
shop.
6. IMPORTANT! The battery should be installed with
the "+" symbol facing up and out of the unit!