Site Preparation
Anti-Tip Bracket Installation
To prevent the unit from tipping forward and provide
a stable installation, the unit must be secured in place
with the anti-tip brackets provided.
IMPORTANT NOTE: Placement of the anti-tip brackets is
critical to a stable installation. Failure to properly position
the anti-tip brackets will prevent them from engaging the
unit.
The two anti-tip brackets must be installed exactly 24"
from the front of the rough opening to the back of the
(610)
brackets and a minimum of 4"
rough opening. This depth will increase to 26
a flush inset installation based on
panels. Proper placement will ensure that the anti-tip
brackets engage the anti-tip bar at the back of the unit.
To properly secure the anti-tip brackets for a stable instal-
lation, use all anti-tip bracket hardware as instructed for
wood or concrete floors.
Anti-Tip Bracket Hardware
2
Anti-tip brackets
1
12
#12 x 2
/
" PH pan HD zinc screws
2
3
3
4
/
"–16 x 3
/
" wedge anchors
8
4
12
#12 flat washers
1
4
#8–18 x 1
/
" PH truss HD screws
4
4
Nylon zip-it wall anchors
from the sides of the
(102)
3
/
"
(665)
16
3
/
"
deep decorative
(19)
4
IMPORTANT NOTE: For either wood or concrete floor
applications, if the #12 x 2
stud or the wall plate in any of the back holes of the
brackets, use the provided #8–18 x 1
screws and #12 flat washers with the nylon zip-it wall
anchors.
IMPORTANT NOTE: In some installations the subflooring
or finished floor may necessitate angling the screws used
to fasten the anti-tip brackets to the back wall.
Make sure there are no electrical wires or plumbing
in the area which the screws could penetrate.
for
1
/
" screws do not hit a wall
2
1
/
" PH truss HD
4
14