Site Preparation
Site Preparation
Make sure that the finished rough opening where the
built-in unit is being installed is properly prepared. Refer to
the overall dimensions and installation specifications for
your specific model. These specifications are identical for
the framed, overlay and stainless steel applications.
Installation specifications are different for the flush inset
application, whether you are using custom panels or
Sub-Zero accessory flush inset panels.
Make sure the opening dimensions, door and drawer
clearances, electrical service and plumbing are correct for
the model you are about to install. The floor under the unit
must be level with the surrounding finished floor.
To operate properly, the door must open a minimum of
90°. Use a minimum 3"
(76)
assure a 90° door opening. Allow enough clearance in
front of the unit for full door swing.
If you are installing two built-in units side by side in the
framed, overlay, flush inset or stainless steel application, a
separating filler strip is recommended. Add the filler strip
width to the finished rough opening dimension.
For installation of two built-in units side by side without a
filler strip, a dual installation kit will be necessary.
filler in corner installations to
Electrical Requirements
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes and
ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
Electrical Requirements
Power Supply
Circuit Breaker
Receptacle
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
Do not use an extension cord or two-prong adapter.
Do not remove the power supply cord ground prong.
FRONT VIEW
7"
E
(178)
6"
(152)
1
75
/
"
2
(1918)
FROM
FLOOR
Location of electrical supply.
12
115 V AC, 60 Hz
15 amp
3-prong grounding-type