THW Series Tranquility Water-to-Water (THW) Series 50 & 60Hz Models Residential High Temperature Water-to-Water Geothermal Heat Pumps (Heating Only) Installation, Operation & Maintenance Instructions 97B0063N01 Revision: 30 June, 2008B Table of Contents Model Nomenclature Electrical - Controls General Information User Interface...
4. Inspect all electrical connections. Connections must be clean and tight at the terminals. Locate and verify any HWG or other accessory sensors located in the compressor section. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
Taco slow closing valve can draw up to 35VA. This can overload smaller 40 or 50 VA transformers depending on the other controls employed. A typical pilot operated Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
• Closed Recirculating system is identified by a closed pressurized piping system. • Recirculating open wells should observe the open recirculating design considerations. • NR - Application not recommended. • "-" No design Maximum. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
Field Line Voltage Wiring Field Low Voltage Wiring Figure 6: THW 60Hz Line and Low Voltage Field Line Voltage Wiring Field Low Voltage Wiring Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
Page 14
1. The valve will remain open during a unit lockout. 2. The valve will draw approximately 25-35 VA through the “Y” signal of the thermostat. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
Page 15
CXM board, and a jumper wire from the w/y terminal to the other side (top connection) of the end switch as shown above. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
100°F [38°C]. The valid range for the heating differential value (HTD) is 4-20°F [2-11°C], adjustable in 2°F [1°C] increments, with a default value of 6°F [3°C]. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
Page 18
24VAC output from the THW unit can energize the boiler. The boiler control box simply needs a relay that can be used to interface with the THW unit. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
When any one of these factors is at minimum or maximum levels, the other two factors should be at normal levels to ensure proper unit operation. Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B...
97B0063N01 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.