Summary of Contents for Kilotech KWS-SW series

  • Page 1 Kilotech KWS-SW Series Counter-top weighing scale NTEP (USA) and Measurement Canada approved www.kilotech.com...
  • Page 2 NOTE: Le manuel en Français est disponible au www.kilotech.com. Thank you for purchasing a Kilotech Model KWS SW Weighing Scale. Please read all operating instructions carefully before using the scale for the first time. This scale is approved by the US and Canadian governments and can be used in a “Legal for Trade”...
  • Page 3: Table Of Contents

    Contents 1.0 Precaution before Using the Scale-----------------------3 ------------------------------------------------------3 1.1 Environment ------------------------------4 1.2 Protection in the transportation -----------------------------------------------4 1.3 Leveling the scale -----------------------------------------------------4 1.4 Turn on scale 2.0 Explanation of Display Symbols--------------------------5 3.0 Keypad Functions---------------------------------------------6 4.0 Operations-------------------------------------------------------6 --------------------------------------------------6 4.1 Weighing mode ---------------------------------------------------8 4.2 Counting mode 5.0 Preset Check-weighing Function-------------------------9...
  • Page 4: Precaution Before Using The Scale

    1.0 Precaution before Using the Scale 1.1 Environment The scale should always be used for its intended use (see www.kilotech.com) and its intended capacity. This scale is not protected against water; DO NOT spray with liquids as this could damage the electronics or could cause serious injury.
  • Page 5: Protection In The Transportation

    1.2 Protection in the transportation Before the initial use, please refer to the following drawing to take off the protection screw. When packing the scale for transportation, install the protection screw on the scale in order to avoid any damage to sensitive components. 1.3 Leveling the Scale The scale is equipped with a level indicator on the left bottom side of the front panel and four adjustable leveling feet.
  • Page 6: Explanation Of Display Symbols

    2.0 Explanation Of Display Symbols LCD Display Meaning of the Symbols (Zero): Scale is in ZERO mode. NET: Scale is in TARE mode. : Low Voltage (Stable): Scale is in stable mode. Kg/g/Ib/oz: Indicates the current measuring units in weighting mode.
  • Page 7: Keypad Functions

    3.0 Keypad Functions Botton Primary Function Secondary Function Accepts the current Zero/Enter Zero the scale setting on the display. Performs a tare Move the active digit Tare/ operation. to the right Changes the weighing Increment the active Units/ Unit.(kg/g, Ib) digit.
  • Page 8 If the user wants to use the HI-LO Check Weighing function, select the weighing mode first. Once in the HI-LO check-weight is selected, the weighing unit can not be changed. Give a long press of “Units/ ” Key to clear the check range and then change the weighing unit.
  • Page 9: Counting Mode

    If regular counting is required, a counting scale would probably be more appropriate. See the KCS 2000 at www.kilotech.com for a true counting scale with 299 item memories and 5000 item memory optional. Sampling (Press Mode/...
  • Page 10: Preset Check-Weighing Function

    5.0 Preset Check-weighing Function Users can set a Hi – Lo range for check-weighing. When the weight of objects on the pan is within, or outside of, the preset weight range, the scale will beep repeatedly and the displayed weight will flicker. Procedures a.
  • Page 11 ★ Within the set parameters type The scale beeps and display value flickers when total weight falls inside the set range. When the weight is outside the set range, display will show “H” or “L” before the total weight. ★ Outside the set parameters type The alarm sounds beeps and display value flickers only when total weight falls outside the set range.
  • Page 12: Scale Parameters Setting

    6.0 Scale Parameters Setting Press Mode/ and Zero/Enter key at the same time in weighing or counting mode to enter into parameters setting. 6.1 Backlight type Press Units/ or Check-W./ to set the backlight type to be “bl. 1”,“bl. 2”or “bl. 3”. Please refer to the following. Model backlight type Description...
  • Page 13: Power Supply & Battery Operation

    7.0 Power Supply & Battery Operation POWER SUPPLY ● Rechargeable battery 6v/5Ah ● DC 9V/700 mA BATTERY OPERATION The scale can be operated from the battery if desired. The battery life is approximately 80 hours. When the battery needs charging a symbol “ ”...
  • Page 14: Error Message

    8.0 Error message During the initial power-on testing it is possible the scale may show error message. The meaning of the error messages is described below. Error Possible causes Remedy codes EPROM data lose. Recalibrate the scale. 1. Check there something on the pan initial zero...
  • Page 15 This should be done by a specialized scale professional. If your distributor is an industrial scale dealer, he will be able to do this for you. If you do not know who to contact, call the Kilotech customer service desk at 800-694-4445 (Canada) or 877-328-5988 (USA)