Specification Top and Front View Interface Details...
Page 4
Calibration switch location ≥500mA, central positive: Power Supply: AC Adapter: 7-9V USB power supply if USB interface is installed 51/2-digit,7-segment , 0.58” (15mm) LCDs Display: Keypad: 3 push buttons Environment: Working temperature: -10°C to 40°C ...
Faceplate Symbols on LCD screen turn on when scale is at zero point and the gross weight is 0 2.2 lb turn on when measure unit is lb 2.3 oz turn on when measure unit is oz 2.4 kg turn on when measure unit is kg 2.5 NET turn on when net weight is displaying, and the tare weight is not 0;...
Operation Menu Structure Normal weighing mode (Calibration Switch is off) Under normal weighing mode, when the seal switch is off, use MENU key to toggle between AL.ON, WT.ON, or AL.OFF, which meaning Backlight On, Backlight auto on when key operation or weight changing, and auto off after 30s elapsed, or Backlight Off.
Page 7
Under normal weighing mode, when the seal switch is on, press MENU key, “CAL” will be shown in display Calibration Switch is on window, press MENU key to shift between “USER”, “END” or “CAL”, and press ZERO key to confirm to enter into the menu.
Page 8
USER Submenu USER Submenu1 Submenu2 Option Default Remark RS232 Source of the executed command selection: NONE NONE: no any command will be executed ; USB: command from COM1 will be executed; CMD.SR RS232: command from COM2 will be RS232 executed; USB.RS: command from USB or RS232 will be USB.RS executed...
Config setting Calibration Switch is on Under normal weighing mode, when the seal switch is on, long press MENU + ON/OFF key, “CONFG” will be shown in display window, press MENU key to shift between “CAL”,“USER”, “MISC”, “TEST”,“END” or “CAL”, and press ZERO key to confirm to enter into the menu.
Weighing operation: Power on scale: when scale is off, press ON/OFF key to turn on; Power off scale: when scale is on, press and hold ON/OFF key to turn off the scale. ZERO: When the weight is stable and within the zero range (2%FS) , press ZERO key to set new zero point. How to change weight unit With the calibration switch on, turn on the scale and enter into normal weighing mode.
Config menu In normal weighing mode, when the seal switch on, long press MENU + ON/OFF key, “CONFG” will be shown in display window, press MENU key to shift between “CAL”,“USER”, “MISC”, “TEST”,“END” or “CAL”, and press ZERO key to confirm to enter into the menu. USER MISC TEST...
Serial Communication Serial port: Wires come from RS232 connector, and TXD1, RXD1 and GND are used. USB port: Wires come from USB connector, and TXD0, RXD0 and GND are used. The baud rate and byte format is set by USER-COM-BAUD.RT and USER-COM-BYT.FMT. Responses to serial commands will be immediate, or within one weight measure cycle of the scale.
TYPE-0 and TYPE-1 INTERFACE ► Most P OS Systems, ECRs and some TEC P OS Systems. 1) PROTOCOL <ENQ> ------------→ Initiate communication ←------------ <DC2> ------------→ Request of weight data <ACK> : Acknowledge the request of weight data ←------------ Inquiry ←------------ <STX>...
TYPE-4 INTERFACE ► NCI ECR(NCR2170), SAMSUNG ER-5100,ER-5115, CRS .etc 1) PROTOCOL <W> ------------→ <CR> ------------→ Inquiry ←------------ ←------------ <LF> XX.XXX LB <CR> <LF> S b1b2 <CR><ETX> ←------------ lb CASE ←------------ <LF> XX.XXX KG <CR> <LF> S b1b2 <CR><ETX> XX.XXX = Weight value The Characters L and B The Characters K and G...
Page 17
STATUS ASCII Character ASCII Character Definition (ASCII Code) (ASCII Code) 0 (30H) 0 (30H) 1 (31H) 0 (30H) Motion 2 (32H) 0 (30H) Scale at Zero 0 (30H) 1 (31H) Under capacity 0 (30H) 2 (32H) Over capacity...
TYPE-5 INTERFACE ► NCI GENERAL, SAMSUNG ER-5115, ER-5100 and Most P .O.S Software 1) PROTOCOL <W> ------------→ <CR> ------------→ ←------------ Inquiry ←------------ <LF> XX.XXX LB <CR> <LF> b1b2 <CR><ETX> ←------------ lb CASE ←------------ <LF> XX.XXX KG <CR> <LF> b1b2 <CR><ETX> XX.XXX = Weight value (Decimal point: variable) LB = The Characters L and B KG = The Characters K and G...
Page 19
ii> Simplified Status Codes STATUS ASCII ASCII Definiti Characte Characte (ASCII (ASCII (30H) (30H) Motio (31H) (30H) Scale at Zero (32H) (30H) Under capacity (30H) (31H) Over capacity (30H) (32H)
TYPE-6 INTERFACE ► 8 Data bit ► None parity ► 1 stop bit ► SAMSUNG ECR (ER-670) 1) PROTOCOL EXTERNAL DEVICE POS SCALE <ENQ> ------------→ Initiate communication ← <ACK> : Acknowledge the request of weight data ----------- → <DC1> or <DC2> ----------- DC1 : For Weight Data DC2 : For All Data ←...
Page 21
TYPE-7 INTERFACE ► Continuous output Continuous output <STX> XXXXX.XX^oz<ETX> or <STX> XXXXXXX^oz<ETX> <STX> XXXX.XXX^kg<ETX> or <STX> XXXXX.XX^kg<ETX> <STX> XXXX.XXX^lb<ETX> or <STX>XXXXX.XX^lb<ETX> TYPE-8 INTERFACE ► Output when stable Output when stable When the scale shows a positive weight and stable signal it will broadcast once the following data train. <STX>...
Connectors and Jumpers Overview of Connectors or jumpers on PCB Load Cell Connector 5±0.3 Vdc (≤0.12A) DEFINITION IN/OUT/POWER ELECTRICAL LEVEL Excitation + Power output Sense + Power input 5±0.3 Vdc ≤0.5 Vdc Excitation- Power ground 0Vdc Sense - Power input Signal + Signal Input 2.5±0.3 Vdc...
PIN # DEFINITION IN/OUT/POWER ELECTRICAL LEVEL GND of VDD Power ground 0Vdc USB D+ 0-5Vdc USB D- 0-5Vdc USB Power Power input 5±0.25 Vdc Calibration switch CONNECTED FUNCTION PINS push Calibration Enabled No push Calibration Disabled NET Socket J2 and J3: used for display ...
Page 24
Troubleshooting SYMPTOM PROBABLE CAUSE REMEDY Ad﹉﹉﹉ Load cell wires to indicator are Make sure wires are ok and correctly incorrectly connected, or shorted, or connected. Replace load cell or ADC opened; or ADC, load cell are Ad﹍﹍﹍ chip, Service required. damaged Weight reading exceeds Power On Make sure scale platform is empty.
Page 27
Maitre'D Setup (Maitre'D Millennium, and later versions of Maitre'D) Maitre'D Setup System Configuration / View / Options / Devices Scale Type: Weigh-Tronix 6710 (lbs) Note: Other than the scale's weight limit, the interface is also limited to a maximum price of 99.99 P.O.S.
Page 28
P.O.S. Control / Revenue center / Items Setup / Function Function: Scale Division: Weight P.O.S. Control / Revenue center / Items Setup / Links If necessary, enter a weight, in thousandth of pounds, in the Tare field.
Page 29
Cabling From DB-9 Female DB-9 Male Pin 2 ---------------- Pin 2 Pin 3 ---------------- Pin 3 Pin 5 ---------------- Pin 5 Shell ---------------- Shell Pin 4 --| Pin 6 --|-- Jumped together Pin 8 --| Scale Setup Set CAL switch into calibration mode ...
Page 30
Press zero key to confirm screen will show CMD.SR Press menu key to confirm and go to next step Screen will show INTFC press zero to confirm Press menu key to scroll. Select TYPE 2 and press zero key to confirm ...
Page 31
Pc America Setup Scale Setup Set CAL switch into calibration mode Turn on scale Press menu key to enter call mode screen will show CAL Press menu key screen will show USER Press zero key Screen will show COM ...
Page 32
Setup CRE/RPE Once the KPOS 1530 has been setup and connected to the computer, and powered on you can configure it in CRE/RPE. To configure the scale in CRE/RPE Select Setup and then Setup Screen Under the Hardware tab, use the Weight Scale Type as Weightronics NCI-6720 then selecting the appropriately...