Location - Carrier 58CTW Installation, Start-Up, Operating And Service And Maintenance Instructions

Variable ---speed, ecm induced ---combustion 2 ---stage deluxe 4 ---way multipoise gas furnace series 100
Hide thumbs Also See for 58CTW:
Table of Contents

Advertisement

5 15/16
5 15/16
[150.7]
[150.7]
AIR FLOW
AIR FLOW
5 1/2
5 1/2
[140.3]
[140.3]
Ø7/8
Ø7/8
8 7/16
8 7/16
[22.2]
[22.2]
[213.5]
[213.5]
ACCESSORY
ACCESSORY
9 7/8
9 7/8
[250.7]
[250.7]
Ø1/2
Ø1/2
[12.7]
[12.7]
27 3/4
27 3/4
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
[704.7]
[704.7]
33 1/4
33 1/4
[843.9]
[843.9]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
21.6
21.6
[549.5]
[549.5]
BOTTOM INLET
BOTTOM INLET
28.39
28.39
[721.2]
[721.2]
29 29
[736.9]
[736.9]
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM ---16 ---in. (406 mm) round or 14 1/2 x 12 ---in. (368 x 305 mm) rectangle.
b. For 1200 CFM ---20 ---in. (508 mm) round or 14 1/2 x 19 1/2 ---in. (368 x 495 mm) rectangle.
c. For 1600 CFM ---22 ---in. (559 mm) round or 14 1/2 x 22 1/16 ---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets,
a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
A
CABINET
FURNACE SIZE
WIDTH
045--- 12/036045
14-3/16 (360)
070--- 16/048070
17--- 1/2 (445)
090--- 16/048090
21 (533)
110--- 22/066110
21 (533)
135--- 22/066135
24-1/2 (622)
*135 size furnaces require a 5 or 6 ---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete
installation requirements.
4. If you touch ungrounded objects (and recharge your body
with static electricity), firmly touch a clean, unpainted
metal surface of the furnace again before touching control
or wires.
5. Use this procedure for installed and uninstalled (ungroun-
ded) furnaces.
6. Before removing a new control from its container, dis-
charge your body's electrostatic charge to ground to pro-
tect the control from damage. If the control is to be in-
stalled in a furnace, follow items 1 through 4 before
bringing the control or yourself in contact with the fur-
nace. Put all used and new controls into containers before
touching ungrounded objects.
7. An ESD service kit (available from commercial sources)
may also be used to prevent ESD damage.
5.1
5.1
[130.5]
[130.5]
2 1/16
2 1/16
[51.6]
[51.6]
1.7
1.7
[43.5]
[43.5]
C
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY (2)
ACCESSORY (2)
1 15/16
1 15/16
[49.2]
[49.2]
AIR FLOW
AIR FLOW
2 5/16
2 5/16
3 7/16
3 7/16
[59]
[59]
[86.8]
[86.8]
5 7/8
5 7/8
[148.5]
[148.5]
TOP OF CASING
TOP OF CASING
Ø7/8
Ø7/8
[22.2]
[22.2]
JUNCTION BOX
JUNCTION BOX

LOCATION

LOCATION
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
6.1
6.1
[155.7]
[155.7]
BOTTOM RETURN
BOTTOM RETURN
WIDTH
WIDTH
B
C
TOP AND
OUTLET
BOTTOM FLUE
WIDTH
COLLAR
12-9/16 (319)
9-5/16 (237)
15-7/8 (403)
11-9/16 (294)
19-3/8 (492)
13-5/16 (338)
19-3/8 (492)
13-5/16 (338)
22-7/8 (581
15-1/16 (383)
Fig. 3 - - Dimensional Drawing
5 7/8
5 7/8
[148.5]
[148.5]
5 7/16
5 7/16
A A
[138.5]
[138.5]
B
TOP OF CASING
TOP OF CASING
4 13/16
4 13/16
[122.2]
[122.2]
9 9/16
9 9/16
[243.3]
[243.3]
27 3/4
27 3/4
[704.7]
[704.7]
J.BOX PROVISION
J.BOX PROVISION
29 9/16
29 9/16
[750.7]
[750.7]
ACCESSORY
ACCESSORY
KNOCK OUTS FOR
KNOCK OUTS FOR
D
3/4
3/4
VENTING(5
VENTING(5
[19.1]
[19.1]
PLACES)
PLACES)
D
VENT
BOTTOM
CONNECTION
INLET WIDTH
SIZE
12--- 11/16 (322)
4 (102)
16 (406)
4 (102)
19--- 1/2 (495)
4 (102)
19--- 1/2 (495)
4 (102)
23 (584)
4 (102)
GENERAL
This multipoise furnace is shipped in packaged configuration.
Some assembly and modifications are required when used in any
of the four applications shown in Fig. 4.
NOTE:
For high- -altitude installations, the high- -altitude
conversion kit MUST be installed at or above 5500 ft. (1676 M)
above sea level. Obtain high- -altitude conversion kit from your
area authorized distributor.
5
8 5/8
8 5/8
[219]
[219]
6 13/16
6 13/16
[172.3]
[172.3]
5 5/8
5 5/8
AIR FLOW
AIR FLOW
[143.3]
[143.3]
19 19
1 15/16
1 15/16
[481.7]
[481.7]
[49.2]
[49.2]
OUTLET
OUTLET
Ø1/2
Ø1/2
[12.7]
[12.7]
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
Ø7/8
Ø7/8
[22.2]
[22.2]
Ø7/8
Ø7/8
[22.2]
[22.2]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
22 1/16
22 1/16
[560]
[560]
SIDE INLET
SIDE INLET
(BOTH SIDES)
(BOTH SIDES)
ACCESSORY
SHIP WT. LB
FILTER MEDIA
(KG)
CABINET SIZE
107 (49)
126 (57)
140 (64)
152 (69)
163 (74)
LOCATION
7 13/16
7 13/16
9 11/16
9 11/16
[197.8]
[197.8]
[245.4]
[245.4]
11 7/16
11 7/16
[290.7]
[290.7]
14 7/8
14 7/8
[337.3]
[337.3]
(BOTH SIDES)
(BOTH SIDES)
1 1/4
1 1/4
[31.8]
[31.8]
1
[25.4]
[25.4]
A10290