Carrier 58CTW Installation, Start-Up, Operating And Service And Maintenance Instructions page 34

Variable ---speed, ecm induced ---combustion 2 ---stage deluxe 4 ---way multipoise gas furnace series 100
Hide thumbs Also See for 58CTW:
Table of Contents

Advertisement

SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
Fig. 45 - - Horizontal Left Application - - Vent Elbow Up
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
Fig. 46 - - Horizontal Left Application - - Vent Elbow Right
1. For common vent, vent connector sizing and vent material: United States- -- -use the NFGC.
2. Immediately increase to 5- -in. (102 mm) or 6- -in. (152 mm) vent connector outside furnace casing when 5- -in. (127 mm) vent
connector is required, refer to Note 1 above.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
factory- -approved Downflow Vent Guard Kit is used in the downflow position. See Product Data Sheet for accessory listing.
4. Type- -B vent where required, refer to Note 1 above.
5. A 4- -in.(102 mm) single- -wall (26 ga. min.) vent must be used inside furnace casing and when the factory- -approved Downflow Vent
Guard Kit is used external to the furnace. See Product Data Sheet for accessory listing.
6. Accessory Downflow Vent Guard Kit required in downflow installations with lower vent configuration. See Product Data Sheet for
accessory listing.
7. Chimney Adapter Kit may be required for exterior masonry chimney applications. Refer to Chimney Adapter Kit for sizing and
complete application details. See Product Data Sheet for accessory listing.
8. Secure vent connector to furnace elbow with (2) corrosion- -resistant sheet metal screws, spaced approximately 180_ apart.
9. Secure all other single wall vent connector joints with (3) corrosion resistant screws spaced approximately 120_ apart. Secure Type- -B
vent connectors per vent connector manufacturer's recommendations.
A03215
A03216
VENTING NOTES FOR FIG. 36 - - 48
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
Fig. 47 - - Horizontal Right Application - - Vent Elbow Left
Fig. 48 - - Horizontal Right Application- -Vent Elbow Left
34
then Up
SEE NOTES: 1,2,4,5,7,8,9
A03219
A02068