Jenn-Air 8181P367-60 Installation Manual page 5

Downdraft range
Table of Contents

Advertisement

ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS
NOTE:
A risk of rangetip over existsif the applianceis
1/8" pilot holein the center of each hole as shown
not installedin accordancewith the installation
in figure6. (A nail or awl may be used if e drillis
instructions provided.The proper useof this device
not available), Secure the ANTI-TIP bracketto the
minimizesthe riskof TIP-OVER. In usingthis devicethe
wall with the two screws providedas shown in
consumermuststillobservethe safety precautions as
figure6. Proceedto STEP 3.
statedin the USE and CARE MANUAL and avoid using
the oven door and/orlowerdrawer as a step stool.
B. Cement or Concrete Construction:
1. Suitablescrewsfor concreteconstructioncan be
Installation instructions are providedfor wood and cement
obtainedat a hardwarestore. Drill the required
in eitherfloor or wall. Any other type of construction may
size hole for the screws obtainedintothe
requirespecialinstallation techniquesas deemed
concreteat the center of the holes identifiedin
necessary to provideadequatefasteningof the ANTI-TIP
figure 5 as "HOLES FOR FLOOR'. Secure the
bracketto the floor or wall.
ANTI-TIP bracketto the floor. Proceed to STEP 3,
STEP 1 - Locating The Bracket (see figure 5)
STEP 3 - Range Installation
A. Determine where either the right or left rear "edge" of
the range will be located and mark the floor or wall.
A. Align the range to its designated location and slide it
back into position. Make sure that the leveling foot is
B. Place the BRACKET 15/16" from the marked "EDGE"
fully inserted into and secured by the ANTI-TIP
toward center of opening and against the back wall as
bracket. Note: A minimum clearance of 114"is
shown in figure 5.
required between the range and the leveling foot that
C. Use the bracket as a template and mark the required
will engage the ANTI-TIP bracket, see figure 6.
holes, as shown in figure 5 for the type of construction
B. For safety considerations as well as optimum
you will be using,
performance adjust the range so that it is level. This
may be checked by placing a spirit level or a large
STEP 2 - Anti-Tip Bracket Installation
pan of water on the cooktopor the oven rack.
A. Wood Construction:
Jenn-Air rangesrequiretotal removalfrom cabinet
1. Floor:Locatethe center of the two holes identified
before an adjustmentcan be made.
in figure 5 as "HOLES FOR FLOOR". Drill a 1/8"
pilothole in the center of each hole(a nailor awl
C. To checkthe rangefor properinstallationof the
may be used if a drill is not available).Secure the
anti-tipbracket:Use a flashlightand look underneath
ANTI-TIP bracketto the floor withthe two screws
the bottomof the rangeto see that one of the rear
provided.Proceedto STEP 3.
levelinglegs is engaged in the bracketslot.
2. Wall: Locatethe center of the two holesidentified
D. Proceedwiththe remainderof the installation
in figure5 as "HOLES FOR WALL. Ddllan angled
instructions.
NOTE;
USE A MINIMUM
OF" (2)
SCREWS
TO INSTALL
ANTI-TIP
BRACKET
TO THE WALL OR FLOOR.
_ O_1ENTATI O1_
HOLE
,
t
HOLES FOR
/
BRACKET
;CREWS MUST
ENTER WOOD
SCREW BRACKET
RANGE
OR METAL,
TO WALL
BOTTOM
iiii
'
..........
-
SL,OE
.N
.7
.1,,"
t
BRACKET
W
TO SECURE
[6mm]
/ E=.._
_ [ _
_
/
////////J"
"///////////////////J
OF RANGE
_]_RK_GEDGE
HOLES FOR
_'_"l
FL00
FIGURE 5
FIGURE 6
-5-

Advertisement

Table of Contents
loading

Table of Contents