PROPANE GAS (LP) TO NATURAL GAS CONVERSION INSTRUCTIONS
TO CONVERT
APPLIANCE
FOR USE WITH
NATURAL
GAS
1. Replace all orifice hoods,..
Perform step 1
through 4 on pages 12 & 13, Locate the (4) four
Natural Gas hoods (with small numbersstamped on
their sides)saved from originalNatural Gas model. The
two hoodswith .0520 (#55 orifice)stamped on them
are for the left frontand left rear burners.The two
hoodswiththe .0595 (#53 orifice)stamped on them are
for the two right burners.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "D") on
pages 13 and 14.
2, Invert cap in pressure regulator (see illustration
"A"). With the appliance installed, the regulator Is
located on the center underside of the appliance at the
inlet to the gas manifold. Identify the type of regulator
on the unit and follow the instructions in the appropriate
illustration.
Manifold - Natural Gas pressure required - 5" Water
3. Adjust low flame setting for each burner. Follow the
Column.
instructionsfor burner low flame adjustment on page
14 to increase the simmer flame size.
Incoming Natural Gas pressure requiredto regulator - 6" -
7" Water Column.
Natural Gas inputrequired - 36,000 BTU/hr.
INCHES
BURNER
BTU/hr
ORIFICE
DIAMETER
COLOR
Left Rear (LR)
8,000
#55
.0520
Brass
Left Front (LF)
8,000
#55
.0520
Brass
Right Rear (RR)
10,000
#53
.0595
Brass
Right Front (RF)
10,000
#53
.0595
Brass