Astria Devonshire36TEN Installation And Operation Instructions Manual

Direct-vent gas fireplace
Hide thumbs Also See for ASTRIA Devonshire36TEN:

Advertisement

P126730-01
P/N 126730-01 Rev C 11/2015
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property
damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
PFS
®
C
US
Report No. F09 -099
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pourrait
d'entraîner des blessures graves, la mort ou des dom-
mages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage de
cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
For more information, visit Astria.US.com
Installation and Operation Instructions
Astria
Direct-Vent Gas Fireplace
®
Models
Devonshire36TEN
Devonshire42TEN
AVERTISSEMENT
Devonshire36TEP
Devonshire42TEP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASTRIA Devonshire36TEN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria ASTRIA Devonshire36TEN

  • Page 1 — L’installation et l’entretien doivent être assurés par un — Installation and service must be performed by installateur ou un service d’entretien qualifié ou par le a qualified installer, service agency or the gas fournisseur de gaz. supplier. For more information, visit Astria.US.com...
  • Page 2 LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO. Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla (vidrio) caliente es proveida con este aparato y deberá instalarse para la protección de los niños y otros individuos en riesgo. Astria.US.com 126730-01C...
  • Page 3: Safety And Your Fireplace

    (Page 26). températures élevées (Page 26) . temperaturas (Página 26).  Lisez L’information de sûreté  Read Important Safety Information  Lea Información importante de importante (Page 4) . (Page 4). seguridad (página 4). [ENGLISH] [FRENCH] [SPANISH] 126730-01C Astria.US.com...
  • Page 4: Important Safety Information

    28. appliance be kept clean. See mainte- conduits de circulation d’air de l’appareil nance instructions on Page 28. soient tenus propres. Voyez les instructions d’entretien à la Page 28. Astria.US.com 126730-01C...
  • Page 5: Table Of Contents

    To help us keep you up-to-date on product information and of- Pre-installation ................8 fers, please take a few moments to register your product online Location of Termination Cap ............11 at Astria.US.com Venting Installation ..............12 Fireplace Installation ..............17 Please read and understand these instructions before installing Installer Instructions ..............
  • Page 6 5. You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. Astria.US.com 126730-01C...
  • Page 7: Local Codes

    • Your direct vent gas fireplace system (fireplace and venting) is a venting instructions very carefully for either vertical or horizontal balanced and sealed gas operating unit. It requires approximately applications. 10-20 minutes of operating time before the flame pattern stabilizes. 126730-01C Astria.US.com...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    • When locating termination cap, it is important to observe the Corner minimum clearances shown in Figure 8, page 11. installation • If recessing into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member. Figure 2 - Common Fireplace Locations Astria.US.com 126730-01C...
  • Page 9 FLANGE LEFT SIDE GAS LINE RIGHT SIDE ELECTRICAL KNOCK GAS LINE OUTLET KNOCK OUT " " " " (36" MODEL) " (36" MODEL) " (42" MODEL) " (42" MODEL) Figure 4 - Electrical Outlet and Gas Knockout Locations 126730-01C Astria.US.com...
  • Page 10 Top of Opening 14" 16" 12" 14" 41" (36") 10" 12" 48" (42") 8" 10" 6" 8" 4" 6" Figure 5 - Framing Clearances with Outside Air Flex Duct 2" 4" Figure 7 - Clearances for Combustible Mantels Astria.US.com 126730-01C...
  • Page 11: Location Of Termination Cap

    Noncombustible Combustible - 6" (15.2 cm) H = 24" (61 cm) G = 12" (30.5 cm) minimum clearance Noncombustible - 2" (5.1 cm) J = 20" (50.8 cm) Figure 8 - Minimum Clearances for Termination Cap 126730-01C Astria.US.com...
  • Page 12: Venting Installation

    (see Figure 10 page 13). • Installation of any component part not manufactured or approved by IHP WARNING: Do not recess vent termination into any • Installation other than as instructed by these instructions wall. This will cause a fire hazard. Astria.US.com 126730-01C...
  • Page 13 (Framing Detail) Vent Opening Noncombustible Wall " Apply Mastic to All Four Sides Vent Cap Center of Hole Wood Screw Figure 10 - Vent Opening Requirements Figure 11 - Installing Horizontal Vent Cap (Noncombustible Exterior) 126730-01C Astria.US.com...
  • Page 14 Exterior Wall with V + H = 40 feet maximum Vinyl Siding H = 20 feet maximum Figure 14 - Typical Horizontal Termination Cap Mounting with Figure 15 - Horizontal Termination Using One 90° Elbow Additional Siding Standoff Installed Astria.US.com 126730-01C...
  • Page 15 45° Elbow Over 11/12 to 12/12 Over 12/12 to 14/12 Over 14/12 to 16/12 Over 16/12 to 18/12 Over 18/12 to 20/12 Over 20/12 to 21/12 Ceiling Firestop Figure 17 - Offset with Wall Strap and 45° Elbows 126730-01C Astria.US.com...
  • Page 16 VR-58 Vertical Restrictor, Galvanized J2292 S-58 Vinyl Siding Standoff, Galvanized J3483 WS-58 Wall Strap J0373 CS-58 Cathedral Ceiling Support J0953 FP-58 Firestop Plate J2316 SF-58 Stucco Flashing - For use with HTS-58 Figure 19 - Vertical Venting Configuration Astria.US.com 126730-01C...
  • Page 17: Fireplace Installation

    1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22). Figure 22 - Gas Connection 126730-01C Astria.US.com...
  • Page 18: Pilot Adjustment

    4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Figure 24 - Equipment Shutoff Valve Correct all leaks at once. Astria.US.com 126730-01C...
  • Page 19 5. Light fireplace (see Operation, page 23). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 23). Door Bottom Latches Access Panel Location Figure 27 - Removing/Replacing Door 126730-01C Astria.US.com...
  • Page 20 2. For 36" models only: Install 3 loose logs by placing log #1, log #2 and log #3 onto one piece log as shown in Figures 29, 29a Figure 29b - Installing Loose Logs #2 and #3 and 29b. Astria.US.com 126730-01C...
  • Page 21 1. Remove battery cover on back of remote control unit. Kink 2. Remove battery. 3. Install 1 A23/12V battery following positive and negative directions. Figure 33 - Connecting/Disconnecting Gas Line to Millivolt Valve 4. Replace battery cover onto remote control unit. 126730-01C Astria.US.com...
  • Page 22: Installer Instructions

    IHP étiquettes d’instructions de sécurité supplémentaires gratuitement. Juego de etiquetas de repuesto - Nº de cat. H8024 Astria.us.com Étiquettes de remplacement, n° cat. H8024 NOTE: English is red text on clear label. French Astria.us.com and Spanish are white text on black label.
  • Page 23: Operation

    This will only last a few hours. 5. Replace center brick/control cover. 1. STOP! Read the safety information above. Incoming Equipment Gas Line Shutoff Valve Figure 35 - Turning Equipment Shutoff Valve to the OFF Position 126730-01C Astria.US.com...
  • Page 24 Rear firebox Blower Plenum Location Location Left Side Shown Note: Refractory Panels and Wires not shown for clarity Speed Control Figure 36a - Blower Kit Location 36'' Models only Figure 36b - Blower Kit Location 42" Models only Astria.US.com 126730-01C...
  • Page 25: Gas Control Module System

    This fireplace is equipped with a battery back-up. If the power was to go out on the fireplace, the battery back-up allows the fireplace to remain operational. Make sure to periodically check the condition of the four AA batteries used for the battery back-up. 126730-01C Astria.US.com...
  • Page 26: Homeowner's Instructions

    Cat. No. H8024 Replacement Label Kit vous plaît contactez IHP ou votre revendeur le plus Juego de etiquetas de repuesto - Nº de cat. H8024 proche pour recevoir IHP étiquettes d’instructions Astria.US.com de sécurité supplémentaires gratuitement. Astria.US.com Étiquettes de remplacement, n° cat. H8024 NOTE: English is red text on clear label.
  • Page 27: Inspecting Burners

    (see Figure • see Troubleshooting, page 29 35, page 23). Do not remove the adjustment screw. • see Troubleshooting, page 29 Sensing Pilot Ignitor/ Burner Sensor Figure 40 - Correct Pilot Flame Pattern Figure 41 - Typical Flame Pattern 126730-01C Astria.US.com...
  • Page 28: Cleaning And Maintenance

    Do not remove if glass is hot. Keep children and pets away from glass. If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 19). Vacuum all glass pieces with a shop vacuum. Astria.US.com 126730-01C...
  • Page 29: Troubleshooting

    If noise is excessive, contact qualified service person Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of and logs curing operation 126730-01C Astria.US.com...
  • Page 30 3. Improper venting or excessive blockage 3. Have vent system inspected, including termination cap. Remove any restrictions or obstruction 4. Excessive amounts of embers and pan 4. Clear excess embers until a minimum gap material of 1/2" remains under grate Astria.US.com 126730-01C...
  • Page 31: Specifications

    HI/LO DC Pilot Motor Drive Control Valve Main Module Power Orange Module Black BATTERY PACK Brown Black SIZE SIZE SIZE SIZE "AA" "AA" "AA" "AA" Black To Ground Brown To Rocker Switch Brown Black Black To J-Box Power Adapter 126730-01C Astria.US.com...
  • Page 32: Parts

    Devonshire 36" Lp Ledgestone Devonshire42TEP F1561 Devonshire 42" Lp Ledgestone Devonshire36TEP F1552 Devonshire 36" Lp Std Ivory Devonshire42TEP F1562 Devonshire 42" Lp Std Ivory Devonshire36TEP F1553 Devonshire 36" Lp Stk Red Devonshire42TEP F1560 Devonshire 42" Lp Stk Red 33(36") 32(42") Astria.US.com 126730-01C...
  • Page 33 Rail, Barrier 42" • • J7450 • • Barrier, 36" J7456 • • Barrier, 42" J7671 • • • • Retainer, Safety Barrier PARTS AVAILABLE NOT SHOWN F2661 LPDBK2 • • • • **Not a field replaceable part. 126730-01C Astria.US.com...
  • Page 34 Devonshire 42" Ng Herr Red Devonshire42TEP F1559 Devonshire 42" Lp Herr Ivory Devonshire42TEP F1563 Devonshire 42" Lp Herr Red Devonshire42TEP F1561 Devonshire 42" Lp Ledgestone Devonshire42TEP F1562 Devonshire 42" Lp Std Ivory Devonshire42TEP F1560 Devonshire 42" Lp Stk Red Astria.US.com 126730-01C...
  • Page 35 • • J7788 Remote Control • • • • J7774 30" Flex Line • • • • J7789 Wire Harness • • • • J7790 AC Adapter (Power Cord) • • • • **Not a field replaceable part. 126730-01C Astria.US.com...
  • Page 36 Left Front Refractory 36" Ledgestone • • J7835 Center Front Refractory 42" Ledgestone • • J7836 Center Front Refractory 36" Ledgestone • • J7837 Right Front Refractory 42" Ledgestone • • J7838 Right Front Refractory 36" Ledgestone • • Astria.US.com 126730-01C...
  • Page 37 Left Front Refractory 36" White • • J7823 Center Front Refractory 42" White • • J7824 Center Front Refractory 36" White • • J7825 Right Front Refractory 42" White • • J7826 Right Front Refractory 36" White • • 126730-01C Astria.US.com...
  • Page 38: Technical Service

    You can also visit our • fireplace will not produce specified heat web site at Astria.US.com. • propane/LP gas supply might be low (propane/LP units only) You may feel your gas pressure is too low. If so, contact your local REPLACEMENT PARTS gas supplier.
  • Page 39: Warranty

    IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.
  • Page 40 WARRANTY KEEP THIS WARRANTY Model Number Serial Number Date Installed Dealer's Name Dealer's Phone Number Keep receipt for warranty verification Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Table of Contents