18.3 Cooling Capacity Table
MODELS
IWC
LWC
Tamb
16
25
35
43
TC: Cooling Capacity (kW)
IP: Power Input (kW)
IWC: Inlet Water Condenser Temperature (°C)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
18.4 Hydraulic Pump Performance
WH-MDC09
WH-MDC12
12
12
7
7
TC
IP
TC
IP
5.90
1.01
7.65
1.30
7.45
1.59
9.20
2.30
7.00
2.25
10.00
3.60
5.80
2.59
7.60
3.95
WH-MDC14
WH-MDC16
12
12
7
7
TC
IP
TC
IP
8.85
1.50
9.62
1.63
10.00
2.68
10.51
2.85
11.50
4.40
12.20
4.80
9.05
5.01
10.08
5.47