Temperature Limiter To Restrict The Maximum Temperature Of Underfloor Heating Systems; Plug Gs For Mixer Motor; Temperature Sensor - Viessmann VITOLIGNO 200-S Technical Manual

High performance wood gasification boilers for logs up to 50 cm long
Hide thumbs Also See for VITOLIGNO 200-S:
Table of Contents

Advertisement

Control unit
(cont.)
Mixer motor
Required runtime of the mixer motor
for 90 ° ∢
Flow temperature sensor (contact temperature sensor)
4 2
6 6

Temperature limiter to restrict the maximum temperature of underfloor heating systems

Immersion temperature controller
Part no. 7151 728
May be used as a maximum temperature limiter for underfloor heating
systems.
The temperature limiter is installed into the heating flow and switches
the heating circuit pump OFF if the flow temperature is too high.
0
7 2
1 3
Specification
Cable length
Setting range
Switching differential
Breaking capacity
Setting scale
Stainless steel sensor well
DIN reg. no.

Plug gS for mixer motor

Part no. 7415 057
3 pce

Temperature sensor

Immersion temperature sensor for DHW heating as a cylinder tem-
perature sensor (to plug 17 of the extension kit). The contact temper-
ature sensor, which is included as part of the standard delivery of the
extension kit, is used as a return temperature sensor (to plug 2 of the
extension kit).
The sensor well is not included in the standard delivery and must be
ordered separately.
VITOLIGNO 200-S
0.1 A 230 V~
approx. 120 s
4.2 m, fully wired
30 to 80 °C
max. 11 K
6(1.5) A 250 V~
inside the casing
R ½ x 200 mm
DIN TR 1168
Secured with a tie.
Specification
Cable length
IP rating
Sensor type
Permissible ambient temperature
– During operation
– During storage and transport
Contact temperature controller
Part no. 7151 729
May be used as a maximum temperature limiter for underfloor heating
systems (only in conjunction with metal pipes).
The temperature limiter is installed into the heating flow and switches
the heating circuit pump OFF if the flow temperature is too high.
0
7 2
1 3
Specification
Cable length
Setting range
Switching differential
Breaking capacity
Setting scale
DIN reg. no.
Required for mixer motors without a cable.
Immersion temperature sensor
Part no. 7438 702
To capture the temperature in a sensor well.
5.8 m, fully wired
IP 32D to EN 60529
Ensure through design/instal-
lation
Viessmann NTC 10 kΩ at
25 °C
0 to +120 °C
–20 to +70 °C
4.2 m, fully wired
30 to 80 °C
max. 14 K
6(1.5) A, 250 V~
inside the casing
DIN TR 1168