Vitodens 100-W, B1HA/B1KA 26 to 125 Combi Operating

Setting the Central Heating Temperature

Display shows current boiler water temperature
Left side of the display shows current boiler water temperature.
Right side displays current outdoor temperature.
Left side of the display shows current boiler water temperature.
Right side displays current outdoor temperature.
(continued)
Operation with room temperature thermostat
If no outside temperature sensor is connected,
but a room temperature controller is.
If the required room temperature is not achieved,
ensure the boiler water temperature setting is sufficiently
high. In the delivered condition, the boiler water
temperature is set to 158°F (70°C).
Setting the boiler water temperature
Tap the following on-screen buttons:
1.
/ the set boiler water temperature flashes and r
is displayed.
2.
/ until the required boiler water temperature is displayed.
3. OK to confirm.
Weather-compensated operation without room temperature
thermostat
Setting the room temperature
An outside temperature sensor must be connected for
weather-compensated operation and a jumper must be
installed on OT terminals.
Refer to the Installation and Service
Instructions.
In the delivered condition, a parameter value of 20 (or
68 if display converted to °F) is set for central heating.
Should you wish to set a higher room temperature,
increase the parameter value;
reduce it for a lower room temperature.
Refer to 'setting the heating curve' on pages 12 and 13.
Weather-compensated operation with room temperature
thermostat
Setting the room temperature
In the delivered condition, a parameter value of 20 (or
68 if display converted to °F) is set for central heating.
Should you wish to set a higher room temperature,
increase the parameter value;
reduce it for a lower room temperature.
Refer to 'setting the heating curve' on pages 12 and 13.
Call for heat on the room thermostat will activate the
boiler. The boiler will operate based on the selected
outdoor reset curve. When room thermostat is satisfied
the boiler will shut down until the next call by the room
thermostat.