IMP SW/POWER LIMIT (impedance/power limiter detection)
IMP: Not applied to these models.
PL: Power limiter detection value
The voltage value of pin No. 123 of IC2 is displayed,
using 5V/256 as standard.
The port (No. 6) output is controlled by using the in-
put voltage value of pin No. 123 of IC2.
PANEL KEY (K0/K1)
(Panel key of main unit) [Remote control code: –]
A/D of the key fails to function properly when the standard
value is deviated by ±8. In this case, check the constant of
partial pressure resistor, solder condition, etc. Refer to
table.
(Reference voltage: 5 V=100 %)
RX-V559/DSP-AX559
Display (%)
K0
0 - 6
MAIN ZONE ON/OFF
7 - 13
—
14 - 21
—
22 - 31
—
32 - 41
INPUT MODE
42 - 53
STRAIGHT
54 - 63
TONE CONTROL
64 - 72
PRESET/TUNING
73 - 80
SPEAKERS B
81 - 88
SPEAKERS A
89 - 95
—
96 - 100
KEY OFF
IMP:8 PL:245
K0:100 K1:100
HTR-5950
K1
Display (%)
ZONE ON/OFF
—
—
ZONE CONTROL
MULTI CH INPUT
FM/AM
A/B/C/D/E
PRESET
PRESET
MEMORY
TUNING MODE
KEY OFF
RX-V559/HTR-5950/DSP-AX559
K0
0 - 6
PROGRAM
7 - 13
PROGRAM
14 - 21
BASS/TREBLE -
22 - 31
BASS/TREBLE +
32 - 41
INPUT MODE
42 - 53
STRAIGHT
54 - 63
TONE CONTROL
64 - 72
PRESET/TUNING
73 - 80
SPEAKERS B
81 - 88
SPEAKERS A
89 - 95
—
96 - 100
KEY OFF
K1
—
—
—
—
MULTI CH INPUT
FM/AM
A/B/C/D/E
PRESET
PRESET
MEMORY
TUNING MODE
KEY OFF
31