Specifi Cations - Valor 530XAN/XAP Installation Instructions Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

Approvals and Codes
This appliance is certifi ed to ANSI Z21.88a–2007/CSA 2.33a–2007 Vented Gas Fireplace Heater Standard for use in
Canada and USA.
The appliance complies with CGA P.4.1, Testing method for measuring annual fi replace effi ciencies.
The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code,
ANSI Z223.1or the Natural Gas and Propane Installation Code CAN/CGA-B149. Only qualifi ed licensed or trained
personnel should install the appliance.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Altitude (Ft)
Input Max. (Btu/h)
Input Min (Btu/h)
Manifold pressure (in.w.c.)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CAN/CGA - 2.17 Gas fi red appliances for use at high altitudes. In USA, installations may require deration
over 2000' —Check local codes.
Front Trims
Various fronts are available for the 530X engine. This engine may be installed as a free standing, zero clearance or
insert application depending on which style front trim is selected. The front trim style affects the framing cavity,
clearances and position of the engine. A front trim kit is required for all applications and should be on site
when the engine is installed as the parts to make the engine suitable for zero clearance are supplied with the front
trim kits (except 549 front).
Fuel Beds
The 530X engine is available in either natural gas or propane gas and comes equipped with either a simulated log
or coal fuel bed in either fuel. A pebble set is also offered as an optional feature. See Options section in this manual.
Venting options
The 530X engine unit is supplied standard with a rear direct vent outlet and may be converted to a top direct
vent outlet with no extra parts required—see Conversion to Top Outlet for Solid Direct Vent Co-axial Piping in the
Appliance Preparation section further on in this manual.
Direct vent installations (solid piping)
A list of all approved venting accessories is shown on pages 32–33 of this manual.
Direct Vent Co-Linear Installations for Free Standing or Recessed Installations (fl exible piping)
Converts the appliance outlet collars to accept two 3" dia. fl exible liners for installation into existing solid-fuel burning
fi replaces and chimneys. Requires a co-linear adapter at the appliance and either a co-linear terminal or co-linear-
to-co-axial terminal at the top of the chimney. A list of approved venting accessories is shown on pages 32–33 of this
manual.
Gravity Vent Installations – For President Free Standing only 552BVX
Converts this appliance from a direct vent fi replace heater to a gravity vent fi replace heater for use with a 4" "B" type
vent. Use this installation manual in conjunction with the installation manual supplied with the 552BVX kit.
Specifi cations
NG
LPG
0-4500 *
20,500
19,000
6,000
11,600
3.5 – 3.9
10.3 – 10.7
5
11
10.5
14
7 7