INSTALLATION MANUAL
700MNGK / 700MPGK Gas Conversion Kit
Use with Valor G3.5 700M Heater Models ONLY
Kit Contents
• 1 Pilot injector
• 1 Main burner injector elbow
• 1 Air shutter
• 1 Pilot shield
• 1 Minimum rate bypass screw
• 1 Set of conversion labels
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove bypass screw
• Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
• Manometer, to set pressure
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
Specifi cations
* This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
4008354-03
©2021, Miles Industries Ltd.
G3.5 Series
700MN
700MP
Natural
Propane
0-4,500 feet*
26,000
26,000
13,000
11,000
3.5"
10"
5"
11"
10"
14"
750
260
51
30
175
105
WARNING
This conversion kit shall be installed by
a qualifi ed service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fi re, explosion
or production of carbon monoxide
may result causing property damage,
personal injury or loss of life. The
qualifi ed service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specifi ed in the
manufacturer's instructions supplied with
the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.