WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life
- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Open windows
• Extinguish any open flame
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Vous pourrez vous procurer un exemplaire en langue française de cette brochure chez votre concessionnaire
Legend
VENTED GAS FIREPLACE HEATERS
MODEL 937XP
FOR USE WITH PROPANE
INSTALLATION
AND OWNER'S
MANUAL
For Pedestal base with
Contemporary front
or
Legs with Traditional front
Please read this manual
before installing and
operating this heater.
This
appliance
domestic room heating
appliance. It must not be
used
for
purpose such as drying
clothes etc.
is
a
any
other
600B257/01

Advertisement

Table of Contents
loading

Summary of Contents for Valor Legend 937XN

  • Page 1 Legend MODEL 937XN MODEL 937XP FOR USE WITH NATURAL GAS FOR USE WITH PROPANE VENTED GAS FIREPLACE HEATERS WARNING: If the information in this INSTALLATION manual is not followed exactly, a fire or AND OWNER’S explosion may result causing property MANUAL damage, personal injury or loss of life For Pedestal base with...
  • Page 2: Table Of Contents

    CONTENTS SAFETY INFORMATION........................................3 OPTIONS............................................4 GENERAL DATA..........................................4 LOCATION IN THE ROOM ......................................4 SUPPLY GAS............................................. 4 PACK CONTENTS......................................... 6 APPLIANCE PREPARATION......................................6 GAS SUPPLY INSTALLATION..................................... 7 BASE & MAIN APPLIANCE INSTALLATION ................................8 VENT CONNECTION........................................9 GAS LINE CONNECTION..................................... 10 SYSTEM CHECK ........................................
  • Page 3: Safety Information

    SAFETY INFORMATION Due to high temperatures, the appliance should be If any changes are made to the room construction located out of traffic and away from furniture and in the vicinity of the appliance after installation draperies. (e.g. additional mantle etc.) make sure that the changes conform to the installation requirements Children and adults should be alerted to the in this manual.
  • Page 4: Options

    Orifice data OPTIONS For verification only. Do not attempt to drill or otherwise modify the appliance input. Natural Gas Propane #710 CFK Circulating fan kit (For pedestal base only) is available Type No of Dia. Type No of Dia. as an option for this appliance. Operated by a variable speed holes (ins) holes...
  • Page 5 WITH PEDESTAL WITH LEGS Fig. 1 Dimensions & clearances...
  • Page 6: Pack Contents

    PACK CONTENTS APPLIANCE PREPARATION The complete appliance is contained in two packs. One of the Remove the window & logs (see figure 2) alternative base support and front designs will be included - either 6.1.1 Detach the window unit by removing the two knurled pedestal with contemporary fascia or Legs with traditional fascia screws (“A”) and knurled nut (“B”) holding the sides and (See pack 2).
  • Page 7: Gas Supply Installation

    Fit exhaust port cover (see figure 4) GAS SUPPLY INSTALLATION Remove four screws from under the top of the firebox. Fit the exhaust port cover and secure with the four screws. Route the gas supply line to the appliance inlet connection point (see figure 1).
  • Page 8: Base & Main Appliance Installation

    BASE & MAIN APPLIANCE INSTALLATION PEDESTAL BASE 8.1.1 Detach the pedestal front panel by removing two screws. 8.1.2 Place the pedestal in position (see figure 5). The bottom rear of the pedestal must be at least 2½” from the back wall to maintain the 2”...
  • Page 9: Vent Connection

    8.2.9 the bottom and locate the single hole over the bottom Replace the door as follows: door hinge pin (see figure 8). 8.2.9.1 Locate the hinge pin at top of the door into the hole at 8.2.9.3 While keeping the bracket located to the hinge pin, the top of the door aperture (see figure 8).
  • Page 10: Gas Line Connection

    GAS LINE CONNECTION SYSTEM CHECK 10.1 11.1 Open the control panel door. Pressure test the supply line for leaks. 10.2 • Pull off the two control knobs. The appliance and its individual shut-off valve must 10.3 be disconnected from the gas supply piping system Detach the control cover panel (see figure 9):- during any pressure testing of that system at test •...
  • Page 11: Ceramic Fuel Bed Assembly

    12.3 Place the rear log in the retaining cradle behind the rear CERAMIC FUEL BED ASSEMBLY burner tube with its back against the back wall. Center the 12.1 Place the ceramic back wall in position centrally at the log so that the gap to the side wall is the same at each side back of the firebox.
  • Page 12: Controls Operation Check

    12.5 Place the two front logs in position on the front rail of the CONTROLS OPERATION CHECK firebox. It may be necessary to raise the center log slightly in order to fit the left-hand front log. Make sure that 13.1 Refit the control cover panel.
  • Page 13: Aeration Adjustment

    AERATION ADJUSTMENT FASCIA INSTALLATION 15.1 These appliances are equipped with adjustable shutters on both Contemporary front only: Fit the ashlip to the fascia front and rear burner tubes to control primary aeration. unit with 4 screws (see figure 18). The air holes are at the right side of the tubes - See fig 17. The shutters can slide to the right to reduce the air supply or to the left to increase it.
  • Page 14: Venting Check

    VENTING CHECK FINAL CHECK A check for correct venting of combustion products must be made 17.1 Recheck gas control and thermostat operation. before the installed appliance is left with the customer. 17.2 Instruct the owner how to operate the appliance. 16.
  • Page 15: Operating The Heater

    (see fig.17) and brush clean if finished operation the controls. necessary. Make sure that no particles are brushed into the 18.3 The Valor Temperature control system burner tubes. Conventional thermostats regulate the temperature by 20.4...
  • Page 16: Checks

    CHECKS SERVICING 21.1 If you require any attention to your appliance, contact your A periodic visual check of the pilot and burner flames supplier quoting the model number. It will be helpful if the should be made (see figures 22 & 23). appliance serial number can also be quoted.
  • Page 17: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 18 Manufactured by HEATING BIRMINGHAM, ENGLAND Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. © Valor Ltd. 1999...