Installation Planning; Specifi Cations - Valor 700IN Owner's Manual

Table of Contents

Advertisement

Installer—READ THIS FIRST
See the Installer's Checklist provided with the appliance
for installation steps. The checklist is on the reverse side
of the content list for the appliance packaging.
Approval & Codes
This appliance is certifi ed to ANSI Z21.88a-2012 /
CSA 2.33a-2012 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
insert installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in
w.c.)
Minimum Supply
Pressure (in w.c.)
Maximum Supply
Pressure (in w.c.)
Main Burner Injector
Marking
Pilot Injector Marking
Min. Rate By-Pass Screw

Installation Planning

Specifi cations
NG
LPG
Natural
Propane
0-4,500 feet*
26,000
25,000
10,000
11,000
4.0
10.0
5.0
11.0
10.0
14.0
750
260
51
30
150
105
Only qualifi ed licensed or trained personnel
should install this appliance.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 700IN is used with natural gas.
Heater engine 700IP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 1/2" NPT female and located on
the left hand side of the appliance. A 34" fl ex connector
and shut-off valve are supplied with the appliance. See
the Supply Gas Installation section of this manual.
X
Conversion Kits
The 700 Legend G3.5 is supplied as natural gas or
propane gas and is fi eld convertible between fuels.
See instructions packaged with the conversion kit
700NGK/NPK for further information.
Electrical
The 700 does not require an electrical power source to
operate as a heater. However, if the appliance is fi tted
with a fan, a grounded power source is required.
QUALIFIED