l
Lenses adjustment
(For a zoom lens)
1 Measuring instrument 1 None
Video
1
Subject
Tape
Test point
More than 50 m away
None
Adjustment address
1FF
Adjustment
level
OC, 06,08
1) Set up the lenses adjustment
mode.
(This is unnecessary
after the above basic iris adjustment
has been made.)
2) Write the adjustment
data OC, 06 and 08 one after the other to the address 1 FF. The adjustments
are as follows.
3) Write FF to the address 1 FE to exit the lenses adjustment
mode.
Data
Adjustment
oc
MR sensor adjustment
06
Wide-end
focus 00 position adjustment
08
Tele-end
focus 00 position adjustment
6-2-2-3.
Before starting these adjustments,
set up the lenses adjust.
l
Sync level adjustment
Measuring instrument
Oscilloscope
Subject
Anything
Tape
Test point
VIDEO OUT (Terminated in 75R)
Adjustment address
23B
i
1 Adjustment
level
1 286mVp-p
I
1) Set up the camera signal adjustment
mode. (Write 00 to the address 1 FE)
2) Push the lens select switch and out the signal of the zoom lens.
3) Connect the oscilloscope
to the VIDEO-OUT.
Adjust the sync level to 286mVp-p.
6-2-2-4.
l
Iris AE adjustment
(For a zoom lens)
Measuring instrument
Oscilloscope
Subject
Gray scale
Tape
Test point
VIDEO-OUT
Adjustment address
1FD
Adjustment
level
700mVp-p
b
1) Shoot the gray scale in the standard way. Observe the VIDEO-OUT
signal on the oscilloscope
screen and rewrite the
data of address 1 FD to get an amplitude
of 700mVp-p
as shown above.
6-2-2-S.
l
Carrier balance , AF noise level adjustment
(For both of
1 Measuring instrument 1 None
I
lenses)
Subject
Tape
Anything
Test point
None
Adjustment
address
1 FF
1 Adjustment
level
1 01
1) Preparation
: write FF to address 19C, 19D, 19E, 19F, lA0, 1Al for a zoom lens.
Write FF to address 309, 30A, 30B, 3OC, 30D, 30E for a wide angle lens.
2) Write the data 01 to the address IFF.
The following
adjustments
are automatically
carried on ; @ Carrier balance adjustment
@ AF noise level adjustment
at AGC Gain Min , AGC Gain Max and Gain up.
6-21