1. Adjustment
of fixed data writing
ADD
DATA
(l)Before
starting
Y/C adjustment,
be sure to write the
23
00
25
00
26
DO
*
2. Adjustment
of input Y level
Measuring instrument
Oscilloscope
, Mode
VCR STOP
. Input signal
Color bar
Measuring
point
TL801 or TL8826
Adjustment
address
32
Adjustment
level
500 mVp-p & 20 mVp-p
specific data in the addresses
listed left.
If the data listed left is written
after Y/C adjustment,
adjusting values may deviate.
Before starting Y/C adjustment,
write 00 to the address
31
At the end of Y/C and LCD adjustment,
write FF to the
address
31.
LCD OPEN +TL801
LCD CLOSE-+TL8826
(1)lnput the color bar signal into the video input/output
terminal in the VCR STOP mode.
(2)Enter the VCR adjustment
mode with an adjustment
remote control, and select the address 32.
Select the address, using the FF or REW key, and fix it with the PB key.
(3)Make an adjustment
so as to get 500 mVp-p between SYNC TIP and WHITE PEAK on TL801 or TL8826.
Select the data, using the FF or REW key, and fix it with the PB key.
After the adjustment,
press the STOP key, and exit from the adjustment
address 32.
3. Adjustment
of playback Y level
Measuring instrument
Oscilloscope
Mode
PB
Playback signal
Color bar (JiGWR5-5NSP)
Measuring
point
TL801 or TL8826
Adjustment
address
27
Adjustment
level
500 mVp-p & 20 mVp-p
LCD OPEN +TL801
LCD CLOSE+TL8826
(l)Set
the color bar tape for adjustment
(JiGWR5-SNSP).
(2)Enter the VCR adjustment
mode with an adjustment
remote control, and select the address 27.
Select the address, using the FF or REW key, and fix it with the PB key. (It will automatically
set the playback mode.)
(3)Make an adjustment
so as to get 500 mVp-p between SYNC TIP and WHITE PEAK on TL801 or TL8826.
Select the data, using the FF or REW key, and fix it with the PB key.
After the adjustment,
press the STOP key, and exit from the adjustment
address 27.
4. Adjustment
of Y-FM carrier f0
Measuring instrument
Frequency
counter
Mode
VCR STOP
Input signal
No input
Measuring
point
TL7401
Adjustment
address
33
Adjustment
level
4.20 + 0.02 MHz
(1)input the no-signal
into the video input/output
terminal in the VCR STOP mode.
At this time, do not pull out the jack on the Viewcam side.
(2)Enter the VCR adjustment
mode with an adjustment
remote control, and select the address 33.
Select the address, using the FF or REW key, and fix it with the PB key.
(3)Make an adjustment
so that the frequency
counter indicates 4.2 MHz on TL7401.
Select the data, using the FF or REW key, and fix it with the PB key.
After the adjustment,
press the STOP key, and exit from the adjustment
address 33.