WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke,
cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.
OBSERVED PROBLEM
Fireplace produces unwanted odors
Gas odor when control knob is in OFF position
or during combustion
Dark residue on logs or inside of fireplace
BCT2536TMN
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Natural
• Orifice Size (Main Burner): #45 DMS (0.082")
• Ignition: Millivolt
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
BCT2536TMP
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Propane/LP
• Orifice Size (Main Burner): #55 DMS (0.052")
• Ignition: Millivolt
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
ALL MODELS
• Fireplace Dimension HxWxD (Actual size of firebox measurements do not include nailing flanges or standoffs): 35.75" x 36.25" x 14.75"
(90.8 x 92.1 x 37.5 cm)
• Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)
126741-01C
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Gas leak. See Warning statement above
1. Gas leak. See Warning statement above
2. Control valve defective
1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked
4. Improper venting or excessive blockage
5. Excessive amounts of embers and pan mate-
rial

SPECIFICATIONS

BCT2536TEN
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Natural
• Orifice Size (Main Burner): #45 DMS (0.082")
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
BCT2536TEP
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Propane/LP
• Orifice Size (Main Burner): #55 DMS (0.052")
• Ignition: Electronic
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
Superiorfireplaces.US.com
REMEDY
1. Locate and correct all leaks (see Checking Gas
Connections, page 14)
1. Locate and correct all leaks (see Checking Gas
Connections, page 14)
2. Replace gas control valve
1. Properly locate logs (see Installing Logs and
Glowing Embers, page 16)
2. Clean out air holes at burner inlets. Periodi-
cally repeat as needed
3. Remove blockage or replace burner
4. Have the vent system inspected, including the
termination cap. Remove any restrictions or
blockage
5. Clear excess embers from around rear main
ports. Use a minimum one layer of smaller
ember pieces to achieve best glowing effect
over visible areas
25