INSTRUCTIONS
1. STOP! Read the safety information, page 20.
2. Turn off all electrical power to the fireplace.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
5. Turn equipment shutoff valve clockwise
(see Figure 31). Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B" in the
safety information, page 20. If you don't smell gas go to the next
step.
7. Turn equipment shutoff valve counterclockwise
position. Do not force.
8. Close lower louver panel.
9. Turn on all electric power to fireplace.
10. Turn wall switch to the ON position.
11. Visually locate pilot. Ignitor should begin to spark and main burner
should ignite once flame appears at pilot.
• If lighting appliance for the first time each season, it may take
several attempts before supply gas can reach pilot and main
burner.
• If appliance will not stay lit after several attempts, follow instruc-
tions in To Turn Off Gas To Appliance, and call your service
technician or gas supplier.
Figure 31 - Turning Equipment Shutoff Valve to the OFF Position
NOTICE: During initial operation of a new fireplace, the
burning of residues from the manufacturing process of
the firebox and logs will produce a paper-burning smell
and orange flames. Open a window for the first few hours
of operation to adequately vent this smell.
18
OPERATING FIREPLACE
ELECTRONIC IGNITION SYSTEM
LIGHTING
to the OFF position
Superiorfireplaces.US.com
Continued
1. Turn off wall switch.
2. Turn off all electric power to appliance if service is to be per-
formed.
3. Open lower louver panel.
4. Turn equipment shutoff valve clockwise
force.
5. Close lower louver panel.
Pilot
Burner
to the ON
Note: The WRC receiver and hand-held remote control kit must be
purchased separately (see Accessories, page 30). Follow installation
instructions included with the remote control.
1. Turn equipment shutoff valve to ON position. You can now turn
burner on and off with hand-held remote unit.
IMPORTANT: Be sure to press the ON/OFF buttons on hand-held
remote control unit for up to 3 seconds to assure proper operation.
2. Press ON/OFF button to turn the burner on and off.
TO TURN OFF GAS
TO APPLIANCE
Ignitor
Sensor
Rod
Figure 32 - Pilot
OPTIONAL WIRELESS
REMOTE OPERATION
to OFF. Do not