Daikin BACnet 2508031 Installation And Maintenance Manual
Daikin BACnet 2508031 Installation And Maintenance Manual

Daikin BACnet 2508031 Installation And Maintenance Manual

Vav actuator room sensor

Advertisement

Quick Links

Installation and Maintenance Manual
BACnet
VAV Actuator
®
Room Sensor
Models 2508031 and 2508032
IM 1038
Group: Controls
Part Number: IM 1038
Date: March 2010

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Reference Documents . . . . . . . . . . . . . . . . . . . . . .2
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .2
Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
General Information . . . . . . . . . . . . . . . . . . . . . . .2
Hazard Identification Messages . . . . . . . . . . . . . .2
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Required Tools and Materials . . . . . . . . . . . . . . . .4
Room Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Mounting Information . . . . . . . . . . . . . . . . . . . .4
Electrical Box and
Rough-in Mounting, Typical . . . . . . . . . . . . . . . .5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BACnet 2508031 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin BACnet 2508031

  • Page 1 Installation and Maintenance Manual IM 1038 Group: Controls Part Number: IM 1038 Date: March 2010 BACnet VAV Actuator ® Room Sensor Models 2508031 and 2508032 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Revision History .
  • Page 2: Revision History

    . Daikin Applied disclaims any liability resulting from any interference or for the correction thereof .
  • Page 3: Getting Started

    ntroductIon Getting Started Application • Review these instructions before beginning . They work with McQuay BACnet VAV Actuator 2508021 and 2508021P10 . These devices incorporate a solid state or 10K • Confirm that appropriate field wiring is installed (standard NTC sensing element to detect temperature . The effective six-conductor room sensor cables, plenum or non-plenum sensing and setpoint range is 55 to 95°F (13 to 35°C) .
  • Page 4: Installing A New Bacnet Vav Actuator

    nstallatIon nstallatIon The following section describes how to field install a new Installing a new BACnet VAV Actuator BACnet VAV Actuator Room Sensor . Expected Install Time: Room Sensor 20 minutes Mounting Information CAUTION Electrostatic discharge hazard. Can cause equipment Always mount the room sensor vertically, on a flat wall.
  • Page 5 nstallatIon Electrical Box and Rough-in Mounting, Typical 2 . Drill two 3/16-inch (4 .8 mm) mounting holes and mount the two plastic wall anchors flush to below the wall CAUTION surface for stable mounting of the device . Over-tightening may cause the room sensor base plate to 3 .
  • Page 6 Daikin Applied Training and Development Now that you have made an investment in modern, efficient Daikin equipment, its care should be a high priority. For training information on all Daikin HVAC products, please visit us at www.DaikinApplied.com and click on Training, or call 540-248-9646 and ask for the Training Department.

This manual is also suitable for:

Bacnet 2508032

Table of Contents