Outdoor Unit (Ras-18Uax4, Ras-18Ua-E4); Outdoor Unit (Ras-18Ua-Ar4); Outdoor Unit (Ras-18Uax4-T2) - Toshiba RAS-18UFHP-E4 Service Manual

Under ceiling/console type
Table of Contents

Advertisement

4-4. Outdoor Unit (RAS-18UAX4, RAS-18UA-E4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-5. Outdoor Unit (RAS-18UA-AR4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-6. Outdoor Unit (RAS-18UAX4-T2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH340X3C-4KT1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
WLF-240-42A-1
Winding resistance (Ω)
(at 20°C)
451155L
AC 450 V, 1.5µF
BUM44X4505B
AC 440 V, 45µF
CLK-26J
220 – 240 V, 50 Hz
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH340X3C-4KTS1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
WLF-240-42B
Winding resistance (Ω)
(at 20°C)
451205L
AC 450 V, 2µF
SK42CMP45U1-S
AC 420 V, 45µF
CLK-26J
220 – 240 V, 50 Hz
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH290X2C-4FT1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T
Winding resistance (Ω)
(at 20°C)
451355L
AC 450 V, 3.5µF
BUM44X3505A
AC 440 V, 35µF
CLK-26J
220 – 240 V, 50 Hz
– 18 –
FILE NO. SVM-05015
Specifications
C-R
1.46
Red-Black
White-Black
188
Specifications
C-R
1.23
Red-Black
White-Black
197
Specifications
C-R
1.71
Red-Black
64.4
C-S
2.47
289
C-S
2.58
255
C-S
3.09
White-Black
127.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents