<Piping and Drain hose installation>
• The piping direction can be the following 3 ways with
the Drain hose.
• Each piping direction should be connected with the
Flexible pipe ".
Side piping
Bottom piping
Fig. 8-4-23
• Cut or remove the determined direction slit or cover.
Cover for side piping
Fig. 8-4-24
8-4-6. Wiring connection
<How to connect the connecting cable>
Rear piping
1. Remove the Terminal cover and the Cord clamp.
2. Insert the connecting cable into the pipe hole on the
3. Insert the connecting cable fully into the Terminal
4. Fix the connecting cable by the Cord clamp with two
5. Fix the Terminal cover.
Slit for upper piping
<Stripping length of the connecting cable>
Cover for rear upper
piping
NOTE:
Use strand wire only.
• Wire type : More than 1.5 mm
NOTE:
Connect the earth line to the metallic part (i mark)
located at the side of 3P terminal.
– 50 –
FILE NO. SVM-05015
Screws
Fig. 8-4-25
wall.
block and secure it tightly with the screw.
Tightening torque: 1.2 N·m (0.12kgf·m)
screws.
40
Fig. 8-4-26
2
IEC66) or 1.3 mm
(AWG-16)
Fig. 8-4-27
Terminal cover
Cord clamp
Earth terminal
50
Earth line
2
(H07RN-F or 245